Analysis of risk factors related to early implant failure: A retrospective study.

J Prosthet Dent

Professor, Department of Stomatology, the First Affiliated Hospital of Wenzhou Medical University, Wenzhou, Zhejiang, PR China. Electronic address:

Published: May 2024

Statement Of Problem: Factors influencing early implant failure (failure during the healing period) in the rehabilitation and restoration of oral function in partially edentulous patients are unclear.

Purpose: The purpose of this clinical study was to investigate several factors that may be associated with early implant failure.

Material And Methods: This retrospective study was conducted on 3247 implants in 2061 patients between 2009 and 2022. Patient-related and surgery-related factors, including smoking; sex; diabetes; bone grafting; implant length, diameter, and design; adjacent teeth; and insertion torque, were manually retrieved and analyzed. Using univariate and multivariate analyses, a generalized estimating equation (GEE) model with chi-squared tests was employed to evaluate factors related to early implant failure (the failure before restoration) (α=.05).

Results: The mean ±standard deviation age of the study patients was 49.2 ±15.0 years (range 18 to 91). Ninety-nine implants (3.05%) failed during the healing period. Three factors were statistically significant regarding early implant failure: smoking (odds ratio [OR]=1.92, P=.008), implant design (tapered implants) (OR=1.84, P=.007), and implant length <10 mm (OR=2.98, P=.011). Factors including diabetes, bone grafting, anatomic location, adjacent teeth (endodontic therapy in the adjacent teeth and the distance between implant and adjacent teeth), healing method, and insertion torque did not exhibit a statistically significant higher early implant failure rate. Ninety-three sites with failed implants received new implants, and 6 of these 93 implants failed during the healing period.

Conclusions: Within the limitation of sample size, smokers, implant length (<10 mm), and implant design (tapered implant) exhibited higher risk of early implant failure in this retrospective study. Implant insertion torque, healing method, adjacent teeth, and diabetes did not significantly influence the risk of early implant failure.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.prosdent.2024.04.026DOI Listing

Publication Analysis

Top Keywords

early implant
20
implant failure
16
factors early
8
implant
8
retrospective study
8
failure failure
8
healing period
8
implant length
8
factors
6
failure
6

Similar Publications

Background: Interventricular dyssynchrony derived from the classic non-physiological stimulation (n-PS) of the right ventricle (RV) is a known cause of left ventricular dysfunction (LVDys).

Methods: This was a prospective descriptive single-center study. We analyzed patients who develop LVDys with n-PS, and the results after upgrading to conduction system pacing (CSP).

View Article and Find Full Text PDF

Radiostereometric Analysis (RSA) is the most accurate method for determining early micromotions of orthopedic implants. Computed Tomography Radiostereometric Analysis (CT-RSA) is a method that can be used to determine implant and bone micromovements using low-dose CT scans. This study aimed to evaluate the reliability of the CT-RSA method in measuring the interfragmental mobility in patients who have undergone a correction osteotomy due to a malunited distal radius fracture.

View Article and Find Full Text PDF

Objectives: Our goal was to measure the impact of postpartum implant insertion timing on breastfeeding success and duration in a population at high-risk for low milk supply.

Study Design: We conducted a three-armed randomized non-inferiority study of postpartum people who plan to breastfeed and have known risk factors for low milk supply. Participants were randomized to one of three groups for the timing of implant placement: within 30 minutes of placental delivery, 24-72 hours postpartum, or 6+ weeks postpartum.

View Article and Find Full Text PDF

Background: Pelvic reconstruction after type I + II (or type I + II + III) internal hemipelvectomy with extensive ilium removal is a great challenge. In an attempt to anatomically reconstruct the hip rotation center (HRC) and achieve a low mechanical failure rate, a custom-made, 3D-printed prosthesis with a porous articular interface was developed. The aim of this study was to investigate the clinical outcomes of patients treated with this prosthesis.

View Article and Find Full Text PDF

Galectin-3 secreted by triple-negative breast cancer cells regulates T cell function.

Neoplasia

December 2024

Felsenstein Medical Research Center, Beilinson Campus, Petah Tikva, Israel; Tel Aviv University, Faculty of Medicine and Health Sciences, Tel Aviv, Israel; Rabin Medical Center, Beilinson Campus, Petah Tikva, Israel; Davidoff Cancer Center, Beilinson Campus, Petah Tikva, Israel. Electronic address:

Triple-negative breast cancer (TNBC) is an aggressive subtype that accounts for 10-15 % of breast cancer. Current treatment of high-risk early-stage TNBC includes neoadjuvant chemo-immune therapy. However, the substantial variation in immune response prompts an urgent need for new immune-targeting agents.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!