Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Sweet, DK, Qiao, J, Rosbrook, P, and Pryor, JL. Load-velocity profiles before and after heated resistance exercise. J Strength Cond Res 38(6): 1019-1024, 2024-This study examined neuromuscular performance using load-velocity (L-V) profiles in men and women before and after resistance exercise (RE) in hot (HOT; 40° C) and temperate (TEMP; 21° C) environments. Sixteen (f = 8, m = 8) resistance-trained individuals completed a single 70-minute whole-body high-volume load (6 exercises, 4 sets of 10 repetitions) RE bout in HOT and TEMP. Before and after RE, rectal temperature (TRE), muscle temperature of the vastus lateralis (TVL) and triceps brachii (TTB), and an L-V profile for the deadlift and bench press were recorded. Thermoregulatory and L-V data were analyzed using separate 2-way repeated measures analysis of variances (ANOVAs; condition [hot, temperate] and time [pre, post]) with significance level set at p ≤ 0.05. Deadlift peak velocity was reduced at 60% 1 repetition maximum (1RM) after RE in HOT but not TEMP. Peak velocity of 40% 1RM bench press was lower in TEMP vs. HOT pre-RE (p < 0.01). Peak velocity was decreased at all loads in the deadlift L-V profile after RE, regardless of condition. Despite elevated TRE (TEMP; 37.58 ± 0.35, HOT; 38.20 ± 0.39° C), TVL (TEMP; 35.24 ± 0.62, HOT; 37.92 ± 0.55° C), and TTB (TEMP; 35.05 ± 0.78, HOT; 38.00 ± 0.16° C) after RE in HOT vs. TEMP (p < 0.01), RE in HOT did not broadly affect L-V profiles. This indicates heated resistance exercise can be performed with high-volume load and high ambient temperature with minimal performance impairment.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1519/JSC.0000000000004739 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!