The aim of the study was to assess the external and internal compatibility of the Biometrics E-LINK EP9 evaluation system device in the area of hand grip and pinch strength in the Polish population. The testing of hand grip and pinch strength was carried out among 122 healthy students. Two examiners performed hand grip and pinch strength measurements with a Biometrics E-LINK EP9 evaluation system device. Measurements were made for the right and left hands. The same people were tested again two weeks later, under the same conditions. The scores of one rater on the first and second tests were compared for reproducibility, and the scores of the two raters were compared to assess the reliability of the instrument. The measurements were found to be highly consistent both between the investigators and between the tests in the hand grip dynamometer test. The findings show high values of the Pearson's correlation coefficient equal or close to 1, as well as the interclass correlation coefficient (ICC) >0.9. Analysis of pinch strength measurements performed using the pinchmeter also found high values of the Pearson's correlation coefficient close to 1, as well as the interclass correlation coefficient >0.9; this reflects high agreement between the measurements performed by two investigators as well as assessments performed by one investigator at time intervals. These findings were confirmed by analyses performed using Bland-Altman plots. The measurements made with the Biometrics E-link EP9 evaluation system show high internal and external consistency in hand grip and pinch strength assessment. Biometrics E-link EP9 can be recommended for daily clinical practice.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11115248PMC
http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0303648PLOS

Publication Analysis

Top Keywords

hand grip
24
pinch strength
24
grip pinch
20
biometrics e-link
16
e-link ep9
16
correlation coefficient
16
ep9 evaluation
12
evaluation system
12
strength polish
8
system device
8

Similar Publications

Hydronium Ions Are Less Excluded from Hydrophobic Polymer-Water Interfaces than Hydroxide Ions.

J Phys Chem B

December 2024

Department of Chemistry, The Pennsylvania State University, University Park, Pennsylvania 16802, United States.

The cloud point temperatures of aqueous poly(-isopropylacrylamide) (PNIPAM) and poly(ethylene) oxide (PEO) solutions were measured from pH 1.0 to pH 13.0 at a constant ionic strength of 100 mM.

View Article and Find Full Text PDF

Objective: To provide clinicians with reliable recommendations for the selection of appropriate suturing techniques for surgical management of common musculoskeletal soft tissue injuries.

Methods: A systematic search of PubMed, Springer, Web Science, Vip Database, China National Knowledge, and Wanfang Data for in vitro biomechanical studies on suture techniques in the surgical treatment of musculoskeletal soft tissue injuries covering relevant studies from April 2009 to April 2024 was performed. A generalized classification was made based on the characteristics of the techniques, and recommendations for the selection of suture techniques were made according to the GRADE concept.

View Article and Find Full Text PDF

Purposes: The objective of this study was to investigate intra-articular distal radius fractures, aiming to provide a comprehensive analysis of fracture patterns and discuss the corresponding treatment strategies for each pattern.

Methods: 294 cases of intra-articular distal radius fractures lines were collected and clustered thorough K-means and hierarchical clustering algorithm. The demographic data of patients and the clinical treatment outcomes were recorded.

View Article and Find Full Text PDF

Pyrocardan® implant interposition in the trapeziometacarpal joint: outcomes at a minimum 10 years' follow-up.

Hand Surg Rehabil

December 2024

Institut de la Main Nantes Atlantique, Boulevard Charles-Gautier, 44800 Saint-Herblain, France.

Objective: We present long-term results for the Pyrocardan®, a pyrocarbon trapeziometacarpal interposition implant used for the treatment of osteoarthritis of the thumb.

Methods: Between March 2009 and May 2013, 199 arthroplasties were performed in a single hand center, in 184 patients by 6 hand surgeons. 107 implants were followed up for a mean 137 months (range, 120 to 168 months).

View Article and Find Full Text PDF

Introduction Spinal fusion surgery with pedicle screws is commonly performed to stabilize the spine of osteoporotic patients. However, securing a strong screw fixation in osteoporotic bone presents significant challenges due to the reduced bone density. This study aimed to compare the biomechanical performance in an osteoporotic bone model of pedicle screws inserted using two different techniques, the Jamshidi needle technique and the pedicle probe technique, as well as the influence of tapping on both these techniques.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!