A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Peri-device leakage and delayed endothelialization of the Watchman device: a computed tomography study. | LitMetric

Objectives: This study aimed to explore the endothelialization process and assess the potential association between endothelialization and peri-device leak (PDL) following Watchman implantation via a quantitative method.

Methods: This is a single-center retrospective study of consecutive patients undergoing LAAO between December 2015 and November 2021. Device endothelialization, compared between PDL and non-PDL group, were quantitatively analyzed based on hypoattenuated thickening in cardiac computed tomography angiography (CCTA). Advancement in endothelialization over time were explored using the Cochran-Armitage test and generalized estimating equation approach. Potential risk factors of delayed endothelialization were analyzed using the Cox proportional-hazards model.

Results: A total of 172 patients (mean age, 68 years ± 10 [standard deviation], 114 men) were finally included. The average endothelialization ratio of the study population was 89.8 ± 7.2 percent. In the follow-up period of postprocedural 3 months to more than 12 months, an incremental trend of endothelialization over time was observed with the ratio of 85.8 ± 8.0, 89.6 ± 7.6, 92.2 ± 4.5, 94.3 ± 2.9 percent, respectively (p < 0.0001). Notably, patients without PDL exhibited a swifter advancement in endothelialization compared to those with PDL, irrespective of device size. The multivariable Cox regression model showed that PDL (HR = 2.113, 95%CI: 1.300-3.435, p = 0.003), DSP (HR = 1.717, 95%CI: 1.113-2.647, p = 0.014) were independent risk factors of delayed endothelialization.

Conclusion: CCTA holds promise as an effective means of quantitatively assessing device endothelialization. Endothelialization advanced gradually over time, with PDL potentially impeding device endothelialization.

Clinical Relevance Statement: A comprehensive understanding of the correlation between endothelialization ratio, time, and residual shunt can establish a more dependable foundation for determining the appropriate anticoagulation treatment following left atrial appendage closure.

Key Points: Current recommendations for postleft atrial appendage occlusion anti-platelet and anticoagulation therapy are based on animal studies. Cardiac computed tomography angiography (CCTA) combined with the UNet neural network model enables the quantitative assessment of device endothelialization. This technique will allow for additional studies to better understand device endothelialization to optimize treatments in this population.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00330-024-10778-5DOI Listing

Publication Analysis

Top Keywords

endothelialization
8
delayed endothelialization
8
computed tomography
8
endothelialization time
8
peri-device leakage
4
leakage delayed
4
endothelialization watchman
4
watchman device
4
device computed
4
study
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!