Sialylation is an important modification of proteins, related to protein life and bioactivity. However, the evaluation of sialylation is only based on the average molecular composition by peptide mapping and glycan profiling because sialylated proteins are usually too heterogeneous to obtain good quality mass spectra by conventional intact mass analysis methods. In this study, a simple strong cation exchange-mass spectroscopy (SCX-MS) method was developed for intact mass analysis of sialylated glycoproteins. The developed SCX-MS method provided good separation for sialylated glycoproteins and had an inherent characteristic of native MS. Thus, the intact mass analysis of highly heterogeneous glycoprotein, which cannot be obtained by reversed-phase liquid chromatography (RPLC)-MS and size exclusion chromatography (SEC)-MS methods, can be well analyzed using the current SCX-MS method. First, the method was developed and optimized using the etanercept monomer. Conditions including MS parameters, flow rate, and gradient were investigated. Then, the developed method was used to analyze a new recombinant vaccine, protein 1. Similar to the etanercept monomer, the intact molecular information of protein 1, which cannot be obtained by RPLC-MS and SEC-MS, can be achieved using SCX-MS. Combined with information obtained on peptide mapping and glycan profiles obtained by LC-MS, the new vaccine was well characterized. Finally, the SCX-MS method was used to quickly evaluate the batch-to-batch reproducibility of protein 1. It was much faster than peptide mapping and glycan profiling methods and can provide information complementary to these strategies. It should be useful for many applications where speed and comprehensive characterization are required, such as recombinant sialylated vaccines and fusion proteins.

Download full-text PDF

Source
http://dx.doi.org/10.1039/d4ay00486hDOI Listing

Publication Analysis

Top Keywords

scx-ms method
16
sialylated glycoproteins
12
peptide mapping
12
mapping glycan
12
intact mass
12
mass analysis
12
glycan profiling
8
method developed
8
etanercept monomer
8
method
6

Similar Publications

An Integrated Strategy to Identify Tyrosine Sulfation from the Therapeutic Proteins.

J Am Soc Mass Spectrom

December 2024

Discovery Analytical Research, Analytical Enabling Capabilities, Merck & Co., Inc., South San Francisco, California 94080, United States.

Posttranslational modifications (PTMs) are potential critical quality attributes in biotherapeutic development, as they can affect drug efficacy and safety. Tyrosine sulfation plays a critical role in protein-protein interactions and has been found on many surface receptors as well as antibody complementarity-determining regions (CDR). However, the presence and function of tyrosine sulfation in therapeutic proteins have not been broadly investigated due to difficulties in detecting the modification.

View Article and Find Full Text PDF

Sialylation is an important modification of proteins, related to protein life and bioactivity. However, the evaluation of sialylation is only based on the average molecular composition by peptide mapping and glycan profiling because sialylated proteins are usually too heterogeneous to obtain good quality mass spectra by conventional intact mass analysis methods. In this study, a simple strong cation exchange-mass spectroscopy (SCX-MS) method was developed for intact mass analysis of sialylated glycoproteins.

View Article and Find Full Text PDF
Article Synopsis
  • Biosimilarity assessment requires detailed comparisons between originator products and potential biosimilars to ensure quality and efficacy, allowing for quicker approvals and lower drug costs.
  • Various analytical methods, including intact native mass spectrometry (MS), help identify important quality attributes and simplify complex protein analyses.
  • This study utilized strong cation exchange chromatography paired with Orbitrap mass spectrometry (SCX-MS) to compare Humira® with seven biosimilars, revealing differences in protein modifications such as N-glycosylation and lysine truncation.
View Article and Find Full Text PDF

Imaged capillary isoelectric focusing (icIEF) and ion-exchange chromatography (IEX) are two essential techniques that are routinely used for charge variant analysis of therapeutic monoclonal antibodies (mAbs) during their development and in quality control. These two techniques that separate mAb charge variants based on different mechanisms and IEX have been developed as front-end separation techniques for online mass spectrometry (MS) detection, which is robust for intact protein identification. Recently, an innovative, coupled icIEF-MS technology has been constructed for protein charge variant analysis in our laboratory.

View Article and Find Full Text PDF

Characterization of charge heterogeneity in monoclonal antibodies (mAbs) is needed during developability assessment and downstream development of drug candidates. Charge heterogeneity can come from post-translational modifications like deamidation, isomerization, and sialylation. Elucidation of charge variants with mass spectrometry (MS) has historically been challenging.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!