A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A New Technique for Harvesting Limbal Stem Cell Tissue for Transplantation Using an Automated Microkeratome and a Novel Globe-Fixation System. | LitMetric

Purpose: To introduce an unprecedented technique, instrumentation, and setup for the superficial limbus harvest from the human cadaver donor whole globe.

Methods: We studied several superficial limbus harvest alternatives, developed a preferred approach with our available instruments, and optimized it on a handful of (seropositive) cadaver donors of whole globes.

Results/technique: The globe was pressurized to about normal intraocular pressure by viscoelastic injection through the optic nerve stump. The globe was then mounted on a dynamic globe fixator that maintained a negative pressure in its stabilizing socket. Exertion of the negative pressure effectively elevated globe intraocular pressure (to over 40 mm Hg) and made the corneoscleral wall tight. The socket was then held tilted to the left side for about 35 to 40 degrees to put the limbal zone horizontally and mildly "chin-up." Next, the microkeratome was put on the uppermost and exposed limbus of the globe and activated, and the socket was rotated clockwise under the microkeratome head and its oscillating blade, allowing an effective 360-degree revolution of the microkeratome head around the limbal belt (for a right-handed operator and a counterclockwise cut).

Conclusions: We consistently succeeded in peeling intact 360-degree strips of the smooth superficial limbus by using blades with varying depths. Our method can be further equipped and optimized and be used by the eye banks and the surgeons for keratolimbal grafting as a more efficient limbal stem cell tissue harvest technique.

Download full-text PDF

Source
http://dx.doi.org/10.1097/ICO.0000000000003572DOI Listing

Publication Analysis

Top Keywords

superficial limbus
12
limbal stem
8
stem cell
8
cell tissue
8
limbus harvest
8
intraocular pressure
8
negative pressure
8
microkeratome head
8
globe
5
technique harvesting
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!