Dimensional accuracy and surface characteristics of complete-arch cast manufactured by six 3D printers.

Heliyon

Department of Prosthodontics & Dental Research Institute, School of Dentistry, Seoul National University, Seoul, Republic of Korea.

Published: May 2024

AI Article Synopsis

  • This study evaluated the accuracy of complete-arch dental casts produced by six different 3D printers, focusing on both horizontal and vertical measurements using low-viscosity resin material.
  • Ten casts were printed from a reference design and analyzed for accuracy through multiple deviation metrics, with surface characteristics examined via advanced microscopy techniques.
  • Results indicated that LCD printers generally had higher accuracy (trueness) compared to DLPa and SLA printers, with specific variations in dimensions and surface quality noted among the different printer types.

Article Abstract

Objective: This in vitro study aimed to quantitatively and qualitatively evaluate and compare the horizontal and vertical accuracies of complete-arch casts produced by six 3D printers with different printing principles and resolutions using a low-viscosity resin material.

Methods: A reference cast was designed by CAD software. The 3D printers used were DLPa (Asiga MAX), DLPk (cara Print 4.0), LCD2o (Ondemand 2 K Printer), LCD2p (Photon Mono X), LCD4s (SONIC 4 K), and SLA (ZENITH U). Ten casts were printed for each 3D printer using a low-viscosity resin. The accuracy of each printed cast was evaluated using shell-to-shell deviations, 12 linear, one angular, and five height deviations, with a reference cast as the control. The surface features of the casts were examined using field-emission scanning electron microscopy (FE-SEM) and digital cameras.

Results: The evaluation of shell-to-shell deviation revealed that DLPa and SLA printers exhibited low trueness values, whereas LCD printers displayed high trueness values. Among the LCD printers, LCD4s and LCD2o exhibited the lowest and highest trueness values, respectively. DLPa printers showed lower trueness values for intercanine and intermolar distances, whereas LCD printers generally demonstrated high trueness values. However, LCD4s exhibited similar trueness values to those of SLA and DLPk. The height deviation was smallest in the anterior area, whereas the largest height deviation occurred in the canine teeth. The surface characteristics indicated that the SLA casts had greater light reflection and blunt canine tips. The FE-SEM observations highlighted that the LCD and DLP printers exhibited varying layer characteristics, with some presenting rough and uneven borders in the anterior lingual area.

Significance: The accuracy of 3D printed casts varied among the 3D printer groups: DLPa and SLA were accurate for shell-to-shell deviation, with DLPa being the most accurate for linear and angular deviations. Regardless of the XY resolution, the DLP printers outperformed the LCD printers. Among the LCD group of 3D printers, higher-resolution LCD4s demonstrated increased accuracy. The SLA exhibited soft layer borders in the FE-SEM owing to its laser spot characteristics and prominent light reflection in the digital camera images.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11109808PMC
http://dx.doi.org/10.1016/j.heliyon.2024.e30996DOI Listing

Publication Analysis

Top Keywords

trueness values
24
lcd printers
16
printers
12
surface characteristics
8
low-viscosity resin
8
reference cast
8
accuracy printed
8
linear angular
8
shell-to-shell deviation
8
dlpa sla
8