A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Ultrasonographic Detective Flow Imaging for Evaluating Parathyroid Adenoma in Patients with Primary Hyperparathyroidism. | LitMetric

Background: Detective flow imaging (DFI) is a new imaging technology that displays low-velocity blood flow, which is difficult to visualize on conventional color Doppler ultrasonography (CDU). In this study, we compared the usefulness of DFI with that of CDU and methoxy-isobutyl-isonitrile (MIBI) scintigraphy for detecting parathyroid adenoma (PA) in patients with primary hyperparathyroidism (PHPT).

Methods: From March 2021 to March 2023, 87 PHPT patients underwent surgery, and 66 had a single PA. We performed preoperative conventional ultrasonography with CDU, MIBI scintigraphy, and DFI for 42 patients (5 males and 37 females; mean age: 61.6 ± 15.4 years).

Results: MIBI scintigraphy detected PA in 85.7% (36/42) patients, and both CDU and DFI detected PA in all patients. The rates of vascularity in PA detected by CDU and DFI were 71.4% (30/42) and 85.7% (36/42), respectively. Vascularity was detected by DFI in 6 patients who were negative for vascularity on MIBI scintigraphy. Furthermore, DFI detected blood supply in 6 of the 12 patients with undetectable blood supply on CDU. Fisher's exact test revealed that high or low blood flow, as determined by DFI, was significantly associated with detection of feeding vessels in PA by CDU (P < 0.001).

Conclusions: DFI was useful for preoperative detection of PA blood flow.

Download full-text PDF

Source
http://dx.doi.org/10.1272/jnms.JNMS.2024_91-213DOI Listing

Publication Analysis

Top Keywords

mibi scintigraphy
16
blood flow
12
dfi
9
detective flow
8
flow imaging
8
parathyroid adenoma
8
patients
8
adenoma patients
8
patients primary
8
primary hyperparathyroidism
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!