A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Optimising craniospinal irradiation for medulloblastoma: a dosimetric comparison of two VMAT planning methods. | LitMetric

Background: Craniospinal irradiation (CSI) poses a challenging planning process because of the complex target volume. Traditional 3D conformal CSI does not spare any critical organs, resulting in toxicity in patients. Here the dosimetric advantages of volumetric-modulated arc therapy (VMAT) using partial arc and avoidance sectors are compared with each other in planning in adult patients undergoing CSI to develop a clinically feasible technique that is both effective and efficient.

Patient And Methods: Eight adult patients treated with CSI were retrospectively identified. In total 16 plans were made. We generated two plans for each patient: 1. VMAT plan using partial arc, namely VMAT_pa. 2. VMAT plan using avoidance sectors, namely VMAT_as. The dose prescribed was 36 Gy in 20 fractions. The dose-volume histogram for planning target volume (PTV) and organs at risk (OAR) (lens, eye, heart, thyroid, lungs, liver, gonads and kidneys) were analysed and compared. Dose parameters of mean dose, V, and V for the PTV were evaluated.

Results: The median length of PTV is 65.58 cm (45.8-79.5). The volume of PTV receiving 95% of the dose (V95%) in both the plans are 97.51% (VMAT_as) and 97.99% (VMAT_pa) ( = 0.121) while V107% are 0.733 and 0.742 for VMAT_as and VMAT_pa, respectively ( = 0.969). The doses of OARs such as lens, eye, liver and gonads were comparable. The mean heart dose was 10.4 and 9.0 Gy in VMAT_as and VMAT_pa plans, respectively ( = 0.005). Significant lower doses to the thyroid, kidneys and lungs were seen in VMAT plans using avoidance sectors.

Conclusion: This study provides a practically useful VMAT planning method for the treatment of CSI and illustrates the ability of VMAT using avoidance sectors to generate highly conformal and homogeneous treatment plans for CSI, while limiting the dose to the relevant OARs.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11108045PMC
http://dx.doi.org/10.3332/ecancer.2024.1700DOI Listing

Publication Analysis

Top Keywords

avoidance sectors
12
craniospinal irradiation
8
vmat planning
8
target volume
8
partial arc
8
adult patients
8
vmat plan
8
volume ptv
8
lens eye
8
liver gonads
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!