Purpose: To compare the visual outcomes and efficacy of opposite clear corneal incision (OCCI) and toric intraocular lens (IOL) implantation in correcting preexisting astigmatism (PEA) in patients undergoing phacoemulsification.
Methods: This prospective interventional comparative study was conducted between June 2022 and January 2023 in patients having cataract with PEA undergoing phacoemulsification. Patients were divided into two groups - group A underwent phacoemulsification with OCCI and group B underwent phacoemulsification with toric IOL implantation. Uncorrected distance visual acuity (UDVA), manifest refractive cylinder, and corneal astigmatism using corneal tomography were measured preoperatively and at 6 weeks postoperatively. The eyes were categorized into three groups with PEA ranging from 1 to 1.5 D, 1.6 to 2 D, and 2.1 to 3 D. Depending upon the white-to-white corneal diameter, the eyes were also categorized into four groups with corneal diameter ranging from 10.5 to 10.9 mm, 11 to 11.4 mm, 11.5 to 11.9 mm, and 12 to 12.4 mm.
Results: Sixty eyes of 60 patients were studied. At postoperative 6 weeks, 83.3% (25 eyes) in the OCCI group and 96.7% (29 eyes) in the toric IOL group achieved UDVA of 6/9 or better. No statistically significant difference was noted between the groups ( P = 0.37). The reduction in mean corneal astigmatism was 0.63 ± 0.37 D in the OCCI group and 0.15 ± 0.12 D in the toric IOL group ( P < 0.001). The residual mean refractive cylinder was 0.60 ± 0.38 D in the OCCI group and 0.05 ± 0.15 D in the toric IOL group at 6 weeks ( P = 0.007).
Conclusion: Both OCCI and toric IOL are effective in correcting PEA. However, in a resource-limited setting, OCCI is a better alternative surgical option for correcting astigmatism of 1-1.5 D during phacoemulsification without requiring additional skills or instruments.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11552809 | PMC |
http://dx.doi.org/10.4103/IJO.IJO_3191_23 | DOI Listing |
Background: To determine whether accounting for posterior corneal surgically induced astigmatism (SIA) would improve toric intraocular lens power calculation prediction error.
Methods: A total of 189 eyes of 148 patients undergoing routine cataract surgery were included in the study. Standard and posterior keratometry were measured pre- and postoperatively.
Korean J Ophthalmol
January 2025
Department of Ophthalmology, Seoul National University Bundang Hospital, Seongnam, Korea.
Purpose: To evaluate the accuracy of toric intraocular lens (IOL) axis prediction between two preoperative measurement devices: the optical biometry (IOLMaster 500 or 700) and the dual Scheimpflug topography (Galilei G4).
Methods: Medical records of 64 eyes from 44 patients who underwent phacoemulsification and posterior chamber toric IOL (Zeiss AT TORBI 709M) implantation between July 2017 and January 2022 were reviewed. All patients underwent preoperative evaluation by optical biometry (IOLMaster 500 or IOLMaster 700) and Galilei G4.
Clin Ophthalmol
December 2024
The Department of Ophthalmology, The Shammas Eye Medical Center, Lynwood, CA, USA.
Purpose: To evaluate the clinical outcomes of a new FDA approved toric aspheric hydrophobic acrylic intraocular lens.
Patients And Methods: This is a single surgeon, single-arm, on-label, non-randomized, prospective observational study. Thirty patients underwent bilateral cataract surgery (60 eyes) with placement of a Clareon™ Toric IOL in each eye.
Graefes Arch Clin Exp Ophthalmol
December 2024
Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, No. 83 Fenyang Road, Shanghai, 200031, China.
Purpose: To compare the precision of the arithmetic mean of surgically induced astigmatism (M-SIA) and the centroid of surgically induced astigmatism (C-SIA) in estimating SIA when predicting the power and axis of toric IOLs under different circumstances.
Methods: 120 eyes of 99 patients undergoing toric IOL replacement in a simple cataract surgery were included in the retrospective study. The predicted position of toric IOL was calculated by Z Calc online calculator and Barrett Toric Calculator with M-SIA (0.
Indian J Ophthalmol
December 2024
University Eye Clinic Maastricht, Maastricht University Medical Center, Maastricht, The Netherlands.
Purpose: To study change in the contact of intraocular lens (IOL) with the posterior capsule with respect to the vertical versus horizontal orientation of the haptic-optic junction of the IOL using intraoperative spectral domain optical coherence tomography (SD-OCT).
Methods: Fifty eyes of 50 patients with senile immature cataract underwent topical phacoemulsification procedure with implantation of a monofocal IOL by a single experienced surgeon. The Rescan 700 SD-OCT system was used for intraoperative imaging.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!