Foreign bodies are encountered relatively often within the practice of general surgery. We present a unique case of a rubber, self-retaining, radiopaque "mushroom-tip" Malecot tube placed for fistula drainage control due to an enterocutaneous fistula (ECF) that became a gastrointestinal foreign body.  A 24-year-old male presented in shock with gunshot wounds to his right chest and right upper abdomen to a Level I trauma center. He required a prolonged hospital stay with additional urological and thoracic procedures and an interventional radiology procedure for hepatic pseudoaneurysm and subsequently developed an ECF. The patient was discharged to a rehabilitation facility with a wound management system (WMS) for ECF drainage but returned to the clinic with chemical burns and skin excoriation due to poorly controlled output and suboptimal WMS fit. A better fitting WMS was employed and a 20-French Malecot catheter was placed to assist with drainage control. The patient later returned with abdominal pain reporting the Malecot advanced forward spontaneously and was not externally visible. CT scan revealed the Malecot across the prior ileocolic anastomosis. After considering potential treatment options, we initially proceeded with aggressive bowel stimulation, and saline enemas hoping the tube would pass through his colostomy. He was discharged and the catheter passed at home a few days later via the stoma. Gastroenterological literature recommends invasive management for sharp, corrosive, or elongated foreign bodies exceeding 6cm in length. This unusual case demonstrates a 30-centimeter (cm) blunt object passing through the small bowel and colon in the absence of an ileocecal valve.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11103909PMC
http://dx.doi.org/10.7759/cureus.58630DOI Listing

Publication Analysis

Top Keywords

malecot tube
8
small bowel
8
foreign bodies
8
drainage control
8
malecot
5
non-surgical management
4
management malecot
4
tube migrating
4
migrating small
4
bowel fistula
4

Similar Publications

Foreign bodies are encountered relatively often within the practice of general surgery. We present a unique case of a rubber, self-retaining, radiopaque "mushroom-tip" Malecot tube placed for fistula drainage control due to an enterocutaneous fistula (ECF) that became a gastrointestinal foreign body.  A 24-year-old male presented in shock with gunshot wounds to his right chest and right upper abdomen to a Level I trauma center.

View Article and Find Full Text PDF

T-tube Duodenostomy for the Difficult Duodenum.

Cureus

December 2022

Hepatopancreaticobiliary Surgery, Grand Strand Medical Center, Myrtle Beach, USA.

Tube duodenostomy has been described as a useful technique in the management of difficult duodenum arising from a variety of pathologies. In addition, the use of a t-tube for the duodenostomy presents a resourceful option in the event of Malecot or other such catheter unavailability. The aim of our study is to describe the technique and outcomes associated with this approach.

View Article and Find Full Text PDF

Complete duodenal necrosis associated with non-traumatic duodenal hematoma requiring emergent pancreatico-duodenectomy.

Int J Surg Case Rep

November 2019

Department of Surgery, London Health Sciences Center, London, ON, Canada; Schulich School of Medicine & Dentistry, Western University, London, ON, Canada.

Introduction: Duodenal necrosis is a rare complication of acute pancreatitis but can occur given the shared blood supply to the head of the pancreas and the duodenum.

Presentation Of Case: A 55-year-old male presented with acute-on-chronic pancreatitis and a duodenal hematoma. The hematoma expanded to occlude the biliary tree and, shortly after, the duodenum necrosed and perforated.

View Article and Find Full Text PDF

Catheters are commonly used to treat and diagnose urinary tract abnormalities in the pediatric population. This pictorial essay reviews commonly placed genitourinary catheters imaged by radiography, fluoroscopy, computed tomography (CT) and ultrasonography (US). The purpose of the catheter, how the catheter is placed, and the imaging findings associated with appropriately positioned catheters as well as misplaced and displaced catheters are described.

View Article and Find Full Text PDF

Objective: To describe a series of children who were hospitalized for a tube-weaning program in the general pediatric ward of a pediatric tertiary university hospital: describe our method, to determine the success rate of our inpatient pediatric tube weaning program, and search for relevant factors linked to its success or failure.

Method: We analyzed the medical files of consecutive children who were hospitalized for gastric-tube weaning over an 8-year period. We analyzed outcomes in terms of feeding and growth with at least 2 years of data.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!