Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Contamination of river water systems by microplastic particles (MPPs) is one of the emerging global environmental concerns with potentially widespread ecological, socioeconomic, and health implications. A wastewater treatment plant (WWTP) processes and treats wastewater to remove pollutants and release safe water into the environment. There has been limited research on the characterization of microplastics and their removal in WWTP in South Asia. In this work, we report on the characterization of microplastics in wastewater and sludge samples (n = 300) from Guheshwori WWTP located on the bank of the Bagmati River in Kathmandu city, Nepal representing inlet, secondary aeration tank (SAT), outlet, and sludge from November 2021 to November 2022. On average, we detected 31.2 ± 17.3 MPPs/L, 11.2 ± 9.4 MPPs/L, 8.5 ± 5.6 MPPs/L, and 6.6 ± 4.8 MPPs/g in the samples collected from inlet, SAT, outlet, and sludge, respectively. Commonly found MPPs were in the form of fiber, fragments, foam, and pellets. Largely, MPPs were red, yellow, white, blue, and black. Among the 44 μm - 150 μm, 150 μm - 500 μm and 500 μm - 5 mm categories of size fractions, the most dominant fractions were 500 μm - 150 μm in inlet, SAT, and sludge, and 150 μm - 44 μm in the outlet sampling unit. The Guheshwori WWTP was able to remove 72.5 % of MPPs on average, that mostly occurred in the inlet. The effluent released into the river and the sludge still contained a significant number of MPPs.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.scitotenv.2024.173324 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!