Parametric response mapping (PRM) is a voxel-based quantitative CT imaging biomarker that measures the severity of chronic obstructive pulmonary disease (COPD) by analyzing both inspiratory and expiratory CT scans. Although PRM-derived measurements have been shown to predict disease severity and phenotyping, their quantitative accuracy is impacted by the variability of scanner settings and patient conditions. The aim of this study was to evaluate the variability of PRM-based measurements due to the changes in the scanner types and configurations. We developed 10 human chest models with emphysema and air-trapping at end-inspiration and end-expiration states. These models were virtually imaged using a scanner-specific CT simulator (DukeSim) to create CT images at different acquisition settings for energy-integrating and photon-counting CT systems. The CT images were used to estimate PRM maps. The quantified measurements were compared with ground truth values to evaluate the deviations in the measurements. Results showed that PRM measurements varied with scanner type and configurations. The emphysema volume was overestimated by 3 ± 9.5 % (mean ± standard deviation) of the lung volume, and the functional small airway disease (fSAD) volume was underestimated by 7.5±19 % of the lung volume. PRM measurements were more accurate and precise when the acquired settings were photon-counting CT, higher dose, smoother kernel, and larger pixel size. This study demonstrates the development and utility of virtual imaging tools for systematic assessment of a quantitative biomarker accuracy.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11100024 | PMC |
http://dx.doi.org/10.1117/12.3006833 | DOI Listing |
Transl Vis Sci Technol
January 2025
School of Optometry and Vision Science, University of New South Wales, Sydney, Australia.
Purpose: The purpose of this study was to develop and validate a deep-learning model for noninvasive anemia detection, hemoglobin (Hb) level estimation, and identification of anemia-related retinal features using fundus images.
Methods: The dataset included 2265 participants aged 40 years and above from a population-based study in South India. The dataset included ocular and systemic clinical parameters, dilated retinal fundus images, and hematological data such as complete blood counts and Hb concentration levels.
Curr Cardiol Rep
January 2025
Department of Cardiac Sciences, University of Calgary and Libin Cardiovascular Institute, Calgary, AB, Canada.
Purpose Of Review: This review evaluates recent advancements in Technetium-99 m pyrophosphate (99mTc-PYP) imaging for transthyretin amyloid cardiomyopathy (ATTR-CM). We summarize the advantages of single-photon emission computed tomography (SPECT) over planar imaging, the potential impact of quantitative methods, and emerging data for quantifying response to therapy.
Recent Findings: The current literature demonstrates the superior diagnostic accuracy of SPECT compared with planar imaging in 99mTc-PYP studies.
J Chem Theory Comput
January 2025
Qingdao Institute for Theoretical and Computational Sciences, School of Chemistry and Chemical Engineering, Shandong University, Qingdao, Shandong 266237, P.R. China.
Milestoning is an efficient method for calculating rare event kinetics by constructing a continuous-time kinetic network that connects the reactant and product states. Its accuracy depends on both the quality of the underlying force fields and the trajectory sampling. The sampling error can be effectively controlled through various methods.
View Article and Find Full Text PDFMethods Protoc
January 2025
Univ. Bordeaux, INRAE, Bordeaux INP, Bordeaux Sciences Agro, UMR 1366, OENO, ISVV, F-33882 Villenave d'Ornon, France.
Procyanidins are widely distributed in plant-derived foods, and consist of flavanol oligomers and polymers. Recently, the crown procyanidin sub-family, characterised by a unique macrocyclic structure, has been identified in grapes and wine. This study reports the development and validation of a rapid and quantitative analytical method measuring crown procyanidin concentration in red and white wines using ultra-high-performance liquid chromatography (UHPLC) coupled with a Q-TOF mass spectrometer.
View Article and Find Full Text PDFInt J Nurs Knowl
January 2025
Nursing Department / Graduate Nursing Program, Federal University of Pernambuco, Recife, Pernambuco, Brazil.
Objective: To clinically validate the nursing diagnosis (ND) inadequate social support network in breastfeeding mothers.
Method: This cross-sectional quantitative study employed clinical indicator accuracy analysis and hierarchical modeling for the etiological factors of the ND inadequate social support network. The study included 285 breastfeeding mothers registered in primary healthcare units.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!