Objectives: The first objective of the study was to compare approaches to eardrum electrode insertion as they relate to the likelihood of introducing an acoustic leak between the ear canal and eartip. A common method for placing a tympanic membrane electrode involves securing the electrode in the canal by routing it underneath a foam eartip. This method is hypothesized to result in a slit leak between the canal and foam tip due to the added bulk of the electrode wire. An alternative approach involves creating a bore in the wall of the foam tip that the electrode can be threaded through. This method is hypothesized to reduce the likelihood of a slit leak before the electrode wire is integrated into the foam tip. The second objective of the study was to investigate how sound transmission in the ear is affected by placing an electrode on the eardrum. It was hypothesized that an electrode in contact with the eardrum increases the eardrum's mass, with the potential to reduce sound transmission at high frequencies.
Design: Wideband acoustic immittance and distortion product otoacoustic emissions (DPOAEs) were measured in eight human ears. Measurements were completed for five different conditions: (1) baseline with no electrode in the canal, (2) dry electrode in the canal but not touching the eardrum, secured underneath the eartip, (3) dry electrode in the canal not touching the eardrum, secured through a bore in the eartip (subsequent conditions were completed using this method), (4) hydrated electrode in the canal but not touching the eardrum, and (5) hydrated electrode touching the eardrum. To create the bore, a technique was developed in which a needle is heated and pushed through the foam eartip. The electrode is then thread through the bore and advanced slowly by hand until contacting the eardrum. Analysis included comparing absorbance, admittance phase angle, and DPOAE levels between measurement conditions.
Results: Comparison of the absorbance and admittance phase angle measurements between the electrode placement methods revealed significantly higher absorbance and lower admittance phase angle from 0.125 to 1 kHz when the electrode is routed under the eartip. Absorbance and admittance phase angle were minimally affected when the electrode was inserted through a bore in the eartip. DPOAE levels across the different conditions showed changes approximating test-retest variability. Upon contacting the eardrum, the absorbance tended to decrease below 1 kHz and increase above 1 kHz. However, changes were within the range of test-retest variability. There was evidence of reduced levels below 1 kHz and increased levels above 1 kHz upon the electrode contacting the eardrum. However, differences between conditions approximated test-retest variability.
Conclusions: Routing the eardrum electrode through the foam tip reduces the likelihood of incurring an acoustic leak between the canal walls and eartip, compared with routing the electrode under the eartip. Changes in absorbance and DPOAE levels resulting from electrode contact with the eardrum implicate potential stiffening of eardrum; however, the magnitude of changes suggests minimal effect of the electrode on sound transmission in the ear.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1097/AUD.0000000000001524 | DOI Listing |
Sensors (Basel)
December 2024
Nencki Institute of Experimental Biology of the Polish Academy of Sciences, 02-093 Warsaw, Poland.
The precise localization of epileptic foci with the help of EEG or iEEG signals is still a clinical challenge with current methodology, especially if the foci are not close to individual electrodes. On the research side, dipole reconstruction for focus localization is a topic of recent and current developments. Relatively low numbers of recording electrodes cause ill-posed and ill-conditioned problems in the inversion of lead-field matrices to calculate the focus location.
View Article and Find Full Text PDFSensors (Basel)
December 2024
Abu Dhabi Maritime Academy, Abu Dhabi P.O. Box 54477, United Arab Emirates.
Electroencephalography (EEG) has emerged as a pivotal tool in both research and clinical practice due to its non-invasive nature, cost-effectiveness, and ability to provide real-time monitoring of brain activity. Wearable EEG technology opens new avenues for consumer applications, such as mental health monitoring, neurofeedback training, and brain-computer interfaces. However, there is still much to verify and re-examine regarding the functionality of these devices and the quality of the signal they capture, particularly as the field evolves rapidly.
View Article and Find Full Text PDFSensors (Basel)
December 2024
Department of Mechanical Engineering, University of Michigan, 2350 Hayward St., Ann Arbor, MI 48109, USA.
In this study, a method for determining the optimal location and orientation of an implantable piezoelectric accelerometer on the short process of the incus is presented. The accelerometer is intended to be used as a replacement for an external microphone to enable totally implantable auditory prostheses. The optimal orientation of the sensor and the best attachment point are determined based on two criteria-maximum pressure sensitivity sum and minimum loudness level sum.
View Article and Find Full Text PDFSensors (Basel)
December 2024
Department of Electrical and Computer Engineering, University of Manitoba, Winnipeg, MB R3T 5V6, Canada.
This paper presents a lens-free imaging approach utilizing an array of light sources, capable of measuring the dielectric properties of many particles simultaneously. This method employs coplanar electrodes to induce velocity changes in flowing particles through dielectrophoretic forces, allowing the inference of individual particle properties from differential velocity changes. Both positive and negative forces are detectable.
View Article and Find Full Text PDFSensors (Basel)
December 2024
Department of Electrical and Computer Engineering, Bucknell University, Lewisburg, PA 17837, USA.
Micropillar array electrodes offer several advantages, such as enhanced mass transport, lower detection limits, and the potential for miniaturization, making them instrumental in the design and fabrication of electrochemical biosensors. The performance of these biosensors is influenced by electrode geometry, including parameters like shape and height, which affect surface area and overall sensitivity. In this study, we designed a microfluidic electrochemical biosensor featuring micropillar array electrodes, modeled in COMSOL Multiphysics.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!