A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Comparison of exon-level copy number variants in CytoScan XON assay and next-generation sequencing in clinical samples. | LitMetric

Comparison of exon-level copy number variants in CytoScan XON assay and next-generation sequencing in clinical samples.

Clin Chim Acta

Department of Laboratory Medicine, Yonsei University College of Medicine, Severance Hospital, Seoul, Republic of Korea. Electronic address:

Published: June 2024

Background And Aims: Next-generation sequencing (NGS)-based copy number variants (CNVs) have high false-positive rates. The fewer the exons involved, the higher the false-positive rate. A CytoScan XON assay was developed to assess exon-level CNVs.

Materials And Methods: Twenty-three clinically relevant exon-level CNVs in 20 patient blood samples found in previous NGS studies were compared with the results from the CytoScan XON and multiplex ligation-dependent probe amplification (MLPA).

Results: Fifteen of the 23 exon-level CNVs were consistent with the NGS results. Among these, eight were confirmed using MLPA. In six out of eight discrepancies between the CytoScan Xon and NGS, MLPA was performed, and three were negative, indicating that the CNVs in NGS were false positives. The CytoScan XON exhibits a sensitivity of 72.7% for small exon-level CNVs, along with a specificity of 100%. The assay could not detect the three exon-level CNVs in PKD1 and TSC2 that were detected using both NGS and MLPA. This could be due to the distribution of the probes in some areas, and the CNV-calling regions containing multiple exons.

Conclusion: The CytoScan XON assay is a promising complementary tool for the detection of exon-level CNVs, provided that the users carefully examine the distribution of probes and calling regions.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.cca.2024.119703DOI Listing

Publication Analysis

Top Keywords

cytoscan xon
24
exon-level cnvs
20
xon assay
12
copy number
8
number variants
8
next-generation sequencing
8
ngs mlpa
8
distribution probes
8
cnvs
7
cytoscan
6

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!