Evaluation of Relative Dentin Abrasivity in Whitening Toothpastes Containing Acids.

Int Dent J

Department of Oral Anatomy and Dental Research Institute, School of Dentistry, Seoul National University, Seoul, Republic of Korea; Center for Future of Dentistry, School of Dentistry, Seoul National University, Seoul, Republic of Korea. Electronic address:

Published: October 2024

AI Article Synopsis

  • This study analyzes the dentin abrasivity of various whitening toothpastes using a specific measuring method (RDA-PE), focusing on those that contain acids.
  • A total of 100 bovine dentin specimens were tested with different whitening toothpastes, including those with hydrogen peroxide and silica, undergoing extensive brushing to measure abrasion levels.
  • Results showed that hydrogen peroxide toothpastes had lower abrasivity compared to silica toothpastes, and particle content in the toothpaste significantly influenced the overall abrasivity values.

Article Abstract

Introduction And Aims: This study aimed to evaluate the relative dentin abrasivity of whitening toothpastes containing acids using the Radioactive Dentin Abrasivity - Profilometry Equivalent (RDA-PE).

Methods: A total of 100 bovine dentin specimens were prepared and assigned to the following groups (n = 10): 5 hydrogen peroxide (HP) whitening toothpastes (WTH1-WTH5) with or without acid (citric acid, ethylenedinitrilotetraacetic acid disodium, and phosphoric acid), 2 whitening toothpastes with silica and containing citric or phosphoric acid (WTS1 and WTS2), one conventional toothpaste (CT), and 2 reference slurries (RS). All specimens were brushed for 4,000 or 10,000 strokes using toothbrush and toothbrushing machine. The average dentin depth was measured using a noncontact profilometery, and the RDA-PE value was calculated based on the RS. The pH of the solution, average particle size, particle content, and particle hardness were measured. The RDA-PE data were analysed using one-way analysis of variance and Tukey's test, and the effects of the 4 measured factors on RDA-PE were investigated via multiple regression analysis.

Results: The RDA-PE values of the HP whitening toothpastes (mean value: 19-46) were significantly lower, whereas those of the silica whitening toothpastes (80 or 111) were similar to those of the RS after 4,000 strokes (100). The RDA-PE values of all whitening toothpastes were significantly lower than the RS values after 10,000 strokes (242). The HP whitening toothpastes were slightly acidic (pH ≤6) compared to the other solutions. The HP (2.9%-3.7%) and silica (8.9% or 9.9%) whitening toothpastes had significantly lower particle content than RS (16.6%). The particle content significantly influenced the RDA-PE values by multiple regression results.

Conclusions: The RDA-PE values of whitening toothpastes varied. The particle content in the solution was a key factor affecting the RDA-PE value.

Clinical Relevance: Whitening toothpastes containing acids did not cause significant dentin abrasion.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11561478PMC
http://dx.doi.org/10.1016/j.identj.2024.04.004DOI Listing

Publication Analysis

Top Keywords

whitening toothpastes
44
particle content
16
rda-pe values
16
dentin abrasivity
12
toothpastes acids
12
values whitening
12
whitening
11
toothpastes
11
relative dentin
8
abrasivity whitening
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!