In the present era, the intricacy of procedures undertaken by a pediatric interventional cardiologist has increased, primarily attributed to dealing with smaller, younger patients with more complex anatomies. To adapt to these smaller and more complex patients, we must adapt our interventions and our equipment to perform these procedures. This article outlines various innovative applications of the SwiftNinja steerable microcatheter within the pediatric cardiac catheterization laboratory.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s00246-024-03516-7 | DOI Listing |
Pediatr Cardiol
May 2024
Department of Pediatrics, University of Cincinnati, Cincinnati, OH, USA.
In the present era, the intricacy of procedures undertaken by a pediatric interventional cardiologist has increased, primarily attributed to dealing with smaller, younger patients with more complex anatomies. To adapt to these smaller and more complex patients, we must adapt our interventions and our equipment to perform these procedures. This article outlines various innovative applications of the SwiftNinja steerable microcatheter within the pediatric cardiac catheterization laboratory.
View Article and Find Full Text PDFFront Cardiovasc Med
December 2023
Department of Pediatric Cardiology, Heart Centre of Excellence, Al Jalila Children's Speciality Hospital, Dubai, United Arab Emirates.
Background: SwiftNINJA (Merit Medical Systems, USA) is a novel steerable microcatheter intended for coronary and peripheral vascular interventions. We evaluate and report the first use of SwiftNINJA in pediatric catheterization of congenital heart defects (CHDs).
Methods: We performed a retrospective clinical data review of children with CHDs in whom SwiftNINJA was used during cardiac catheterization between April 2022 and June 2023.
Asian J Surg
January 2022
Key Laboratory of Imaging Diagnosis and Minimally Invasive Intervention Research, The Fifth Affiliated Hospital of Wenzhou Medical University/Affiliated Lishui Hospital of Zhejiang University/The Central Hospital of Zhejiang Lishui, Lishui, 323000, China. Electronic address:
CVIR Endovasc
November 2019
Department of Radiology, NYU Winthrop Hospital, 259 First Street, Mineola, New York, 11501, USA.
Background/purpose: To study steerable microcatheter (SM) use in moderate and highly difficult vessel selection compared to conventional pre-shaped microcatheter (CM) use.
Material And Methods: An IRB approved, single institution analysis of 40 complex angiographic procedures with and without superselective microcatheter use during an eight-month period in 2017 was performed. Target vessels were deemed moderate or highly difficult to select based on vessel size, tortuosity, and/or angulation during non-selective initial angiography.
Cardiovasc Intervent Radiol
June 2017
Department of Diagnostic and Interventional Radiology, Hokkaido University Hospital, N-14, W-5, Kita-ku, Hokkaido, Sapporo, 060-0848, Japan.
The steerable microcatheter (SwiftNINJA, Sumitomo Bakelite, Tokyo, Japan), which has a remote-controlled flexible tip manipulated using a dial in the handgrip, was recently developed and delivered to the market. This device enables the user to change the angle of the microcatheter tip manually, and potentially makes selective catheterisation easier. We evaluated its unique characteristics and utility in selective catheterisation and coil embolization.