A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

The pEGASUS-HPC stent system for intracranial arterial stenosis: a single-center case series. | LitMetric

Background: Intracranial arterial stenting is a technique for the treatment of symptomatic stenosis. In this single-center retrospective case series we evaluated a novel low profile laser-cut stent with an antithrombogenic hydrophilic polymer coating (pEGASUS-HPC, Phenox GmbH, Bochum, Germany) for the treatment of intracranial stenosis in the setting of acute ischemic stroke and elective cases.

Methods: All patients treated with pEGASUS-HPC for one or more intracranial arterial stenoses at our institution were retrospectively included. Clinical, imaging and procedural parameters as well as clinical and imaging follow-up data were collected.

Results: We performed 43 interventions in 41 patients with 42 stenoses in our neurovascular center between August 2021 and February 2024. Twenty-one patients (51.2%) were female and the mean±SD age was 71±10.8 years. Thirty-seven (86.1%) procedures were performed in the setting of endovascular acute ischemic stroke treatment. Technical or procedural complications occurred in seven patients (16.3%), six in the thrombectomy group and one in the elective group. One stent-related hemorrhagic complication (subarachnoid hemorrhage) occurred in emergency cases and symptomatic intracerebral hemorrhage occurred in one patient treated in an elective setting. Overall stenosis reduction following pEGASUS-HPC stent implantation was 53.0±18.0%. On follow-up imaging, which was available for 16 patients (37.2%) after an average of 32±58.6 days, 62.5% of the stents were patent.

Conclusion: Our single-center case series demonstrates the feasibility of using the pEGASUS-HPC stent system, especially in emergency situations when thrombectomy fails.

Download full-text PDF

Source
http://dx.doi.org/10.1136/jnis-2024-021737DOI Listing

Publication Analysis

Top Keywords

pegasus-hpc stent
12
intracranial arterial
12
case series
12
stent system
8
stenosis single-center
8
single-center case
8
acute ischemic
8
ischemic stroke
8
clinical imaging
8
hemorrhage occurred
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!