Transiliac-Shortening Osteotomy to Treat Ischial Pressure Injury due to Fixed Pelvic Obliquity: A Case Report.

JBJS Case Connect

Department of Plastic Surgery, Children's Mercy Kansas City, Kansas City, Missouri.

Published: April 2024

Case: A 17-year-old adolescent boy with Gross Motor Function Classification System 5 cerebral palsy and neuromuscular scoliosis underwent posterior spinal fusion and segmental spinal instrumentation from T3 to the pelvis. He developed a right ischial pressure injury a few months postoperatively, which persisted despite nonoperative measures. He subsequently underwent an ipsilateral transiliac-shortening osteotomy 16 months after spinal surgery to treat his residual pelvic obliquity and the ischial pressure injury, which healed completely. At the 1-year follow-up visit, there were no further signs of pressure injury.

Conclusion: This case report describes transiliac-shortening osteotomy as a viable treatment option for non-healing ischial pressure injuries secondary to fixed pelvic obliquity.

Download full-text PDF

Source
http://dx.doi.org/10.2106/JBJS.CC.23.00557DOI Listing

Publication Analysis

Top Keywords

ischial pressure
16
transiliac-shortening osteotomy
12
pressure injury
12
pelvic obliquity
12
fixed pelvic
8
case report
8
pressure
5
osteotomy treat
4
ischial
4
treat ischial
4

Similar Publications

Sitting pressure during wheelchair propulsion and handcycling: effects of backrest angle, movement intensity and cushion type.

Disabil Rehabil Assist Technol

November 2024

Department of Human Movement Sciences, Faculty of Behavioural and Movement Sciences, Vrije Universiteit Amsterdam, Amsterdam Movement Sciences, Amsterdam, The Netherlands.

The main aim of this study was to compare sitting pressure (peak pressure index (PPI) and peak pressure gradient (PPG)) between a daily wheelchair and fixed-frame handcycle, thereby assessing the effect of handcycle backrest angle, movement intensity and cushion type. Twenty able-bodied participants performed static and dynamic (two intensities) tests in a wheelchair and handcycle. A honeycomb wheelchair cushion and standard foam handcycle cushion were used.

View Article and Find Full Text PDF

Objective: To explore the surgical technique and clinical outcomes of biological total hip arthroplasty(THA) combined with impacting bone grafting for the treatment of moderate to severe acetabular invagination secondary to rheumatoid arthritis(RA).

Methods: Total of 20 patients(28 hips) with RA secondary to acetabular invagination were treated with THA of bioprosthesis combined with autogenous bone grafting from January 2012 to October 2020, including 5 males(8 hips) and 15 females(20 hips) with an average age of (55.10±4.

View Article and Find Full Text PDF

In this study, we aimed to examine whether a wheelchair cushion placed directly atop a sling seat or deflection of the sling seat compensated by a pad along with the placement of a wheelchair cushion changed sitting pressure. Additionally, we examined whether these additions changed sitting comfort. For twenty healthy adults who consented to participate, measurements were taken for three types of cushions, each with and without padding, under six conditions.

View Article and Find Full Text PDF

Tissue Oxygenation in Individuals with Spinal Cord Injury: A Pilot Study.

Adv Exp Med Biol

October 2024

Institute of Complementary and Integrative Medicine, University of Bern, Bern, Switzerland.

Article Synopsis
  • Pressure injuries (PI) are serious tissue lesions that heal slowly and can lead to infections, primarily affecting individuals with spinal cord injuries (SCI) due to their reduced mobility and sensation.
  • A new alert system utilizing a textile-based near-infrared spectroscopy (NIRS) sensor was developed to monitor tissue oxygen levels (StO) in high-risk areas, such as the buttocks, to prevent PIs.
  • Initial tests demonstrated that ST decreased during prolonged sitting, with SCI subjects experiencing a sharper decline, but recovery was observed, showing the sensor's effectiveness without causing skin irritation.
View Article and Find Full Text PDF

This study aimed to determine the reliability and concurrent validity of a low-cost pressure mapping system (Smart mat) and reference standard pressure mapping (MatScan). Thirty healthy volunteers aged 29.57 ± 4.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!