A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

The Impact of Back Optic Zone Design in Orthokeratology on Visual Performance. | LitMetric

Purpose: To evaluate the visual performance in adolescents undergoing orthokeratology (OrthoK) treatment with two different optical zone diameters (OZDs).

Methods: This randomized, double-masked, self-controlled prospective study was conducted at Tianjin Eye Hospital (Tianjin, China) in June 2022. Thirty-six eligible schoolchildren were enrolled and fitted with corneal refractive therapy lenses with two sizes of OZDs (5 mm [5OZ] and 6 mm [6OZ]). Each participant was randomized to wear the 5OZ in one eye and the 6OZ in the contralateral eye. Subjective visual quality was assessed using visual acuity, refraction, contrast sensitivity function, and visual symptoms, and the objective optical quality was assessed using ocular higher order aberrations (HOAs) and modulation transfer function (MTF).

Results: Thirty-five myopic children completed a 1-month follow-up visit. The 5OZ lens induced significantly smaller treatment zone diameters than the 6OZ lens (P < 0.001). Subjective visual quality did not differ significantly between the two groups. Compared to baseline, aberrations of Z40, coma-like, spherical-like, and total HOAs in both groups increased significantly (P < 0.05). For the 3-mm pupils, spherical aberration in the 5OZ group was significantly higher than that in the 6OZ group (P < 0.05). The MTF value of the 6OZ group was significantly higher than that of 5OZ group for 0.3 and 1.5 cycles per degree for the 3-mm pupils (P = 0.006 and P = 0.026, respectively). However, HOAs or MTF did not differ significantly between the two groups for the 5-mm pupils.

Conclusions: The difference induced by varying OZD was significant only in the smaller pupil condition. The selection of OZD in OrthoK designs in real-world patient management should be done while considering individual pupil size.

Translational Relevance: This study revealed that the objective visual quality of small OZD lenses was only slightly affected for the small pupil size.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11107949PMC
http://dx.doi.org/10.1167/tvst.13.5.12DOI Listing

Publication Analysis

Top Keywords

visual quality
12
visual performance
8
zone diameters
8
subjective visual
8
quality assessed
8
differ groups
8
3-mm pupils
8
5oz group
8
group higher
8
6oz group
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!