Introduction: The aim of the present study is to analyze the clinical-radiological outcomes of patients undergoing knee prosthesis revision surgery using constrained condylar prosthesis (LCCK; Zimmer-Biomet).

Material And Methods: Retrospective study of 89 patients operated on between the years 2008 and 2020 with a minimum of 2 years of follow-up. Clinical outcomes were evaluated using the WOMAC Index score and KOOS scales. Radiological results (radiolucent lines, osteolysis, and cortical hypertrophy) were evaluated by two independent observers. Implant survival was analyzed using the Kaplan-Meier method.

Results: At the end of follow-up, a mean WOMAC Index score of 78.67 and KOOS score of 68.8 were obtained. Radiolucent lines (both non-progressive and progressive) were detected in 83.3% of the patients in the sample. Areas of osteolysis > 5 mm around the components were present in 6.75%. Cortical hypertrophy was seen around the femoral stem in 20.3% of cases, around the tibial stem in 20.3% and around both components in 6.76%. No statistically significant relationship was found between the presence of radiolucent lines, osteolysis or cortical hypertrophy with functional results. Implant survival was 88.1% at 13 years.

Conclusion: The present study shows high survival of LCCK prosthesis in revision surgery. The progressive radiolucencies, were associated with worst clinical outcome.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00590-024-03977-9DOI Listing

Publication Analysis

Top Keywords

radiolucent lines
12
cortical hypertrophy
12
constrained condylar
8
knee prosthesis
8
prosthesis revision
8
revision surgery
8
womac score
8
lines osteolysis
8
osteolysis cortical
8
implant survival
8

Similar Publications

Purpose: To create tridimensional (3D) anatomical models of diaphyseal fractures in dogs (3D AMDFD) and to evaluate the models from their radiographs.

Methods: The study consisted of six stages: preparation of femur from a healthy dog cadaver; digitalization of the bone through a 3D scanner and creation of the base model; creation of a 3D AMDFD based on the image of the base model, 3D modeling carried out to reproduce five different types of diaphyseal fractures; printing the models produced on a 3D printer with a thermoplastic material; insertion of neodymium magnets in the fracture line to allow the assembly and disassembly of the parts; and radiography of 3D AMDFD in lateromedial and craniocaudal positions.

Results: The base model and 3D AMDFD had high precision in the replication of bone structures, like the bone in natura.

View Article and Find Full Text PDF

Purpose: >The aim of this multicenter study was to analyze the potential impact of patient demographics and cementation technique towards the development of radiolucent lines (RLLs) in primary total knee arthroplasty (TKA). It was hypothesized that cementation techniques, including higher cement volume, double-layer cementation technique and hardening in full extension, reduce RLL incidence by improving stability, whereas demographic factors such as age, BMI and smoking may increase RLL risk by affecting bone quality and mechanical loading.

Methods: Altogether, 776 patients (median age: 70.

View Article and Find Full Text PDF

Mid-term outcomes after primary total hip arthroplasty with a cemented short stem in an elderly patient cohort.

Arch Orthop Trauma Surg

December 2024

Department of Orthopedics and Trauma Surgery, Ospedale Civile Maggiore Di Borgo Trento, University of Verona, Piazzale Aristide Stefani, 1, 37126, Verona, VR, Italy.

Purpose: The main objective of this prospective study was to assess clinical, radiographic and safety mid-term outcomes after THA with a short cemented stem in an elderly patient cohort. Moreover, the study aimed at investigating the mid-term survivorship of the implant and the incidence of complications.

Methods: 96 consecutive patients (100 cases) underwent THA with a short cemented stem.

View Article and Find Full Text PDF

Background: Indications for primary total knee arthroplasty (TKA) have become more inclusive of morbidly obese patients, however, higher rates of complications and lower implant survival have also been reported in this population. The purpose of this study was to investigate the mid-term survival, clinical, and radiographic outcomes of a cementless trabecular metal monoblock tibial component in severely obese patients.

Methods: This was a retrospective study of class II and III obese (BMI > 35) patients who received a cementless primary TKA.

View Article and Find Full Text PDF
Article Synopsis
  • Initial hinge designs for total knee arthroplasty had issues with loosening, but this study focuses on contemporary rotating-hinge implants.
  • A retrospective review of 54 surgeries from 2014 to 2018 showed promising outcomes, with a patient demographic mostly of older women dealing with severe knee instability.
  • Results indicated a 95% reoperation-free survival rate at 2 and 5 years, significant improvements in patient-reported quality of life, and no signs of aseptic loosening on follow-up imaging.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!