Diagnostic Accuracy of Optic Nerve Head and Macula OCT Parameters for Detecting Glaucoma in Eyes With and Without High Axial Myopia.

Am J Ophthalmol

Viterbi Family Department of Ophthalmology (J.R., E.W., A.B., C.B., A.J., R.N.W., L.M.Z.), Hamilton Glaucoma Center, Shiley Eye Institute, UC San Diego, La Jolla, California, USA. Electronic address:

Published: October 2024

AI Article Synopsis

  • The study aimed to evaluate how differences in optic nerve head (ONH) and macula optical coherence tomography (OCT) measurements can help accurately detect glaucoma in people with varying levels of axial myopia.
  • A total of 1,156 eyes from glaucoma patients and healthy individuals were analyzed to compare the accuracy of various OCT parameters like retinal nerve fiber layer thickness and ganglion cell thickness.
  • Results showed that diagnostic accuracy was generally high, especially for individuals with high myopia, highlighting the effectiveness of these measurements in identifying glaucoma across different myopia groups.*

Article Abstract

Purpose: To characterize structural differences and assess the diagnostic accuracy of optic nerve head (ONH) and macula optical coherence tomography (OCT) parameters to detect glaucoma in eyes with and without high axial myopia.

Design: Cross-sectional study.

Methods: Three hundred sixty-eight glaucoma and 411 healthy eyes with no axial myopia, 393 glaucoma and 271 healthy eyes with mild axial myopia and 124 glaucoma and 85 healthy eyes with high axial myopia were included. Global and sectoral peripapillary retinal nerve fiber layer thickness (pRNFLT), Bruch's membrane opening minimum rim width (BMO-MRW), ganglion cell inner plexiform layer thickness (GCIPLT), and macula RNFLT (mRNFLT) were compared and the diagnostic accuracy for glaucoma detection was evaluated using the adjusted area under the receiver operating characteristic curve (AUC).

Results: Diagnostic accuracy for ONH and macula parameters to detect glaucoma was generally high and differed by myopia group. For ONH parameters the diagnostic accuracy was highest for global (AUC = 0.95) and inferotemporal (AUC = 0.91) pRNFLT for high myopes and global BMO-MRW for nonmyopes (AUC = 1.0) and mild myopes (AUC = 0.97). For macula parameters, the diagnostic accuracy was higher in high myopes with 6 of the 11 GCIPLT global/sectors having adjusted AUCs > 0.90 compared to nonhigh myopes with no AUCs > 0.90. In all myopia groups, mRNFLT had lower AUCs than GCIPLT.

Conclusions: The diagnostic accuracy for pRNFL and GCIPL was high for high axial myopic eyes and shows promise for glaucoma detection in high myopes. Further analysis is needed to determine whether the high diagnostic accuracy can be confirmed in other populations.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ajo.2024.04.022DOI Listing

Publication Analysis

Top Keywords

diagnostic accuracy
32
high axial
16
axial myopia
16
eyes high
12
healthy eyes
12
high myopes
12
high
10
diagnostic
8
accuracy optic
8
optic nerve
8

Similar Publications

Mathematical models of viral dynamics are crucial in understanding infection trajectories. However, severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) viral load data often includes limited sparse observations with significant heterogeneity. This study aims to: (1) understand the impact of patient characteristics in shaping the temporal viral load trajectory and (2) establish a data collection protocol (DCP) to reliably reconstruct individual viral load trajectories.

View Article and Find Full Text PDF

This is a protocol for a Cochrane Review (diagnostic). The objectives are as follows: To determine the diagnostic accuracy of transtracheal ultrasound for detecting endotracheal intubation in adult patients. Secondary objectives Secondary objectives include assessing the diagnostic accuracy of transtracheal ultrasound amongst the following subgroups: setting (e.

View Article and Find Full Text PDF

Objective: To evaluate the diagnostic accuracy of 18F-FDG-PET/CT compared to conventional imaging modalities (CIM) to detect recurrence of primary salivary gland cancers (SGCs).

Data Sources: Review performed on December 26, 2024, using Embase, CINHAL, MEDLINE, and PubMed.

Review Methods: Two blinded reviewers selected studies reporting diagnostic accuracy of PET/CT in identifying locoregional recurrence and/or metastasis in patients with SGCs.

View Article and Find Full Text PDF

Therapeutic hurdles persist in the fight against lung cancer, although it is a leading cause of cancer-related deaths worldwide. Results are still not up to par, even with the best efforts of conventional medicine, thus new avenues of investigation are required. Examining how immunotherapy, precision medicine, and AI are being used to manage lung cancer, this review shows how these tools can change the game for patients and increase their chances of survival.

View Article and Find Full Text PDF

A planktonic population of bacteria can form a biofilm by adhesion and colonization. Proteins known as "adhesins" can bind to certain environmental structures, such as sugars, which will cause the bacteria to attach to the substrate. Quorum sensing is used to establish the population is dense enough to form a biofilm.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?