A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Development of a novel X-ray fluorescence instrument equipped with a noble gas filter. | LitMetric

Development of a novel X-ray fluorescence instrument equipped with a noble gas filter.

Analyst

Division of Science and Engineering for Materials, Chemistry and Biology, Department of Chemistry and Bioengineering, Osaka Metropolitan University, 3-3-138 Sugimoto, Sumiyoshi, Osaka, 558-8585, Japan.

Published: June 2024

AI Article Synopsis

  • The study introduces a new gas filter-XRF (GF-XRF) instrument designed to reduce background intensity in X-ray fluorescence analysis, improving the detection of elements.
  • The instrument operates by adjusting gas pressure, with specific gases (Ar and Kr) used to filter the X-ray signals of target elements (Ti and Zr) effectively.
  • Results indicated that increasing the pressure of the filtering gas enhanced the signal-to-noise ratio (SNR) for both Ti and Zr, showcasing the instrument's potential for high-sensitivity analytical applications.

Article Abstract

In X-ray fluorescence (XRF) analysis, which has been used to analyze elements in various samples, it is important to decrease the background (BG) intensity. Generally, BG signals are reduced by inserting metal foils of various types and thicknesses between the X-ray tube and sample as primary X-ray filters. In this study, we developed a unique gas filter-XRF (GF-XRF) instrument to easily reduce the BG effect by changing the pressure of the gas to ensure that the absorption edge of the gas element is slightly lower than the energy of the XRF peak of the target element. The advantage of using a gas is that the gas pressure can be altered easily. To evaluate the performance of this instrument, Ti and Zr were selected as target elements, and Ar and Kr were selected as the filtering gases. When the XRF spectra of the Ti sample were recorded using the Ar gas filter, as the Ar gas pressure increased, the background signal in the energy region of the Ti Kα peak decreased, resulting in an increase in the signal-to-noise ratio (SNR) of that peak. When the Kr gas filter was used, both the SNR and the minimum detection limit of Zr improved. These results demonstrate that the unique GF-XRF instrument is useful for high-sensitivity analyses.

Download full-text PDF

Source
http://dx.doi.org/10.1039/d4an00122bDOI Listing

Publication Analysis

Top Keywords

gas filter
12
gas
9
x-ray fluorescence
8
gf-xrf instrument
8
gas pressure
8
development novel
4
x-ray
4
novel x-ray
4
instrument
4
fluorescence instrument
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!