Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 143
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 143
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 209
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3098
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 574
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 488
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Severity: Warning
Message: Attempt to read property "Count" on bool
Filename: helpers/my_audit_helper.php
Line Number: 3100
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3100
Function: _error_handler
File: /var/www/html/application/controllers/Detail.php
Line: 574
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 488
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
The efficacy and safety of new-generation devices (NGDs) for severe aortic regurgitation (AR) have mostly been based on single-arm studies with limited sample sizes. Our goal was to summarize the current evidence on NGDs and compare the safety and efficacy of 'off-label' and 'on-label' devices in NGDs. We searched MEDLINE, Embase, Cochrane Library, and Scopus for articles on transcatheter aortic valve replacement in patients with AR. A total of 31 studies that included 1851 patients were identified through April 2023. Among these, 1067 (57.6%) patients received treatment with 'on-label' devices (JenaValve and J-Valve). For NGDs, the total device success rate at 30 days was 94.5% (on-label: 97.8%, off-label: 89.9%; P < 0.001), the all-cause mortality was 4.2% (on-label: 2.6%, off-label: 5.1%; P = 0.006), permanent pacemaker implantation (PPI) was 8.8% (on-label: 6.9%, off-label: 18.4%; P < 0.001), and the rate of greater-than-mild paravalvular leak (PVL) was 1.2% (on-label: 0.9%, off-label: 3.8%; P = 0.003). On-label devices showed significantly better safety and efficacy in terms of the success rate, PPI, greater-than-mild PVL, and 30 day mortality than off-label devices.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11631339 | PMC |
http://dx.doi.org/10.1002/ehf2.14832 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!