A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Viscoelastic coagulation monitoring parameters in cats with acute arterial thromboembolism. | LitMetric

Background: Hypercoagulability has been documented in cats with cardiac disease. However, hemostatic parameters, including viscoelastic coagulation monitoring (VCM) have not been reported in cats with arterial thromboembolism (ATE).

Hypothesis/objectives: Compare VCM parameters in cats with acute cardiogenic ATE and in control cats.

Animals: Sixteen cats with ATE and 30 control cats.

Methods: Multicenter university-based prospective study. Cardiogenic ATE was diagnosed based on physical examination and by ultrasonographically-diagnosed left atrial enlargement. Viscoelastic coagulation monitor analysis, CBC, serum biochemistry profile and coagulation profile were performed at admission in cats with ATE. Analysis from healthy control cats was performed using blood collected by direct venipuncture. Our objective was comparison of VCM parameters clot time (CT), clot formation time (CFT), alpha angle (Angle), maximum clot formation (MCF), amplitude at 10 and 20 minutes (A10 and A20, respectively) and clot lysis index at 30 and 45 minutes (LI30 and LI45, respectively) between ATE and control cats.

Results: Cats with ATE had a decreased angle compared to control cats, with a median (range) of 43° (30-48°) compared to 47° (14-59°; P = .01). The parameters A10, A20 and MCF were decreased in ATE cats compared to control cats with a median (range) of 19 units (8-32) compared to 22 units (6-38), 24.5 units (11-40) compared to 29 units (10-47) and 29.5 units (13-44) compared to 33.5 units (14-53), respectively (P = .01, .01 and .01, respectively). The parameters CT, CFT, LI30 and LI45 were similar between groups (P = .22, .09, .62 and .34, respectively).

Conclusions And Clinical Importance: Cats with cardiogenic ATE cats have VCM parameters consistent with hypocoagulability compared with healthy cats.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11256171PMC
http://dx.doi.org/10.1111/jvim.17050DOI Listing

Publication Analysis

Top Keywords

cats
14
viscoelastic coagulation
12
vcm parameters
12
cardiogenic ate
12
ate control
12
cats ate
12
control cats
12
coagulation monitoring
8
parameters cats
8
cats acute
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!