A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

AWAKE FIBEROPTIC TRACHEAL INTUBATION AND AT-RISK EXTUBATION IN A PATIENT WITH ANTICIPATED DIFFICULT AIRWAY DUE TO POST-TRAUMATIC ANKYLOSIS OF TEMPOROMANDIBULAR JOINTS. | LitMetric

In this case report we present successful airway management in a patient with predicted difficult airway using the Difficult Airway Society guidelines. Our patient presented with recurrence of severely reduced mouth opening due to post-traumatic bilateral temporomandibular ankylosis, and was scheduled for surgical resection of the mandibular articular processes. Awake fiberoptic intubation was planned. After light sedation and thorough topicalization of the nasal cavity the flexible optic bronchoscope was successfully navigated into the trachea with 'spray-as-you-go' technique and the endotracheal tube was railroaded over it. After a two-point check of the endotracheal tube placement the patient was put under anesthesia. The surgery was uneventful. Finally, a plan with surgeons for safe extubation was made and the patient was extubated uneventfully on the next day using the airway exchange catheter in the intensive care unit.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11090226PMC
http://dx.doi.org/10.20471/acc.2023.62.s1.18DOI Listing

Publication Analysis

Top Keywords

difficult airway
12
awake fiberoptic
8
extubation patient
8
endotracheal tube
8
patient
5
airway
5
fiberoptic tracheal
4
tracheal intubation
4
intubation at-risk
4
at-risk extubation
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!