Integration of renewable energy sources (RES) to the grid in today's electrical system is being encouraged to meet the increase in demand of electrical power and also overcome the environmental related problems by reducing the usage of fossil fuels. Power Quality (PQ) is a critical problem that could have an effect on utilities and consumers. PQ issues in the modern electric power system were turned on by a linkage of RES, smart grid technologies and widespread usage of power electronics equipment. Unified Power Quality Conditioner (UPQC) is widely employed for solving issues with the distribution grid caused by anomalous voltage, current, or frequency. To enhance UPQC performance, Fractional Order Proportional Integral Derivative (FOPID) is developed; nevertheless, a number of tuning parameters restricts its performance. The best solution for the FOPID controller problem is found by using a Coati Optimization Algorithm (COA) and Osprey Optimization Algorithm (OOA) are combined to make a hybrid optimization CO-OA algorithm approach to mitigate these problems. This paper proposes an improved FOPID controller to reduce PQ problems while taking load power into account. In the suggested model, a RES is connected to the grid system to supply the necessary load demand during the PQ problems period. Through the use of an enhanced FOPID controller, both current and voltage PQ concerns are separately modified. The pulse signal of UPQC was done using the optimal controller, which analyzes the error value of reference value and actual value to generate pulses. The integrated design mitigates PQ issues in a system at non-linear load and linear load conditions. The proposed model provides THD of 12.15% and 0.82% at the sag period, 10.18% and 0.48% at the swell period, and 10.07% and 1.01% at the interruption period of non-linear load condition. A comparison between the FOPID controller and the traditional PI controller was additionally taken. The results showed that the recommended improved FOPID controller for UPQC has been successful in reducing the PQ challenges in the grid-connected RESs system.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11093348 | PMC |
http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0300145 | PLOS |
Sci Rep
January 2025
ENET Centre, VSB-Technical University of Ostrava, Ostrava, 708 00, Czech Republic.
Steam condensers are vital components of thermal power plants, responsible for converting turbine exhaust steam back into water for reuse in the power generation cycle. Effective pressure regulation is crucial to ensure operational efficiency and equipment safety. However, conventional control strategies, such as PI, PI-PDn and FOPID controllers, often struggle to manage the nonlinearities and disturbances inherent in steam condenser systems.
View Article and Find Full Text PDFSci Rep
January 2025
Department of EEE, JCT College of Engineering and Technology, Coimbatore, Tamil Nadu, 641105, India.
This manuscript proposes the Jellyfish Search Optimization (JSO) algorithm-based Fractional Order Proportional-Integral-Derivative (FOPID) controller tuning for a paper machine headbox. The novelty of this method lies in integrating the JSO technique for optimizing the parameters of the FOPID controller to monitor and control headbox pressure and stock level efficiently and effectively. The JSO algorithm ensures optimal tuning of controller parameters by minimizing error indices such as Integral of Squared Error (ISE), Integral of Time Absolute Error (ITAE), and Integral of Absolute Error (IAE).
View Article and Find Full Text PDFSci Rep
December 2024
School of Electrical Engineering, Vellore Institute of Technology, Chennai, 600127, India.
Spherical tanks have been predominantly used in process industries due to their large storage capability. The fundamental challenges in process industries require a very efficient controller to control the various process parameters owing to their nonlinear behavior. The current research work in this paper aims to propose the Approximate Generalized Time Moments (AGTM) optimization technique for designing Fractional-Order PI (FOPI) and Fractional-Order PID (FOPID) controllers for the nonlinear Single Spherical Tank Liquid Level System (SSTLLS).
View Article and Find Full Text PDFSci Rep
November 2024
Hourani Center for Applied Scientific Research, Al-Ahliyya Amman University, Amman, Jordan.
This paper introduces the Walrus Optimization Algorithm (WaOA) to address load frequency control and automatic voltage regulation in a two-area interconnected power systems. The load frequency control and automatic voltage regulation are critical for maintaining power quality by ensuring stable frequency and voltage levels. The parameters of fractional order Proportional-Integral-Derivative (FO-PID) controller are optimized using WaOA, inspired by the social and foraging behaviors of walruses, which inhabit the arctic and sub-arctic regions.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!