Background: Pulmonary vein isolation (PVI) employing cryoballoon (CB) or contact force-guided radiofrequency (CF-RF) catheter ablation has been established as an effective strategy for managing atrial fibrillation (AF). However, its efficacy in hypertrophic cardiomyopathy (HCM) remains to be further explored.

Methods: This retrospective study analyzed 60 consecutive AF patients with HCM (average age 67 ± 10 years; 41 men) who were consecutively admitted to our hospital from January 2014 to December 2022 and underwent initial PVI.

Results: The patients were treated with CB (26 patients) or CF-RF (34 patients). Successful PVI was achieved in both groups without significant complications. In the CF-RF group, additional ablations were performed on the cavotricuspid isthmus (14.7% of patients) and the anterior line (2.9%). The CB group benefited from reduced procedural times (93 ± 31 vs. 165 ± 60 min, p < 0.05) and decreased saline irrigation requirements (77.5 ± 31.4 vs. 870 ± 281.9 mL, p < 0.0001). Using a contrast medium was exclusive to the CB group (33.8 ± 4.2 mL). In a 12-month follow-up, the atrial tachyarrhythmia recurrence-free rates in the CB and CF-RF groups were comparable (77% and 76%, respectively; p = 0.63 according to the log-rank test). Notably, pulmonary vein reconnection was prevalent in most (7 out of 8) patients requiring a secondary ablation procedure.

Conclusion: PVI is feasible as a strategy for AF in patients with HCM employing either CB or CF-RF techniques. While the recurrence-free rates were comparable in both groups, differences were noted in procedure duration, saline usage, and the need for a contrast medium.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s10840-024-01822-xDOI Listing

Publication Analysis

Top Keywords

pulmonary vein
8
vein isolation
8
atrial fibrillation
8
hypertrophic cardiomyopathy
8
patients
6
comparing cryoballoon
4
cryoballoon contact-force
4
contact-force guided
4
guided radiofrequency
4
radiofrequency ablation
4

Similar Publications

Lower red blood cell count is a risk factor for higher D-dimer level in patients with spinal cord injury: A five year retrospective cross-sectional study.

J Spinal Cord Med

January 2025

Rehabilitation Medicine Center and Institute of Rehabilitation Medicine, West China Hospital, Sichuan University, Chengdu, People's Republic of China.

Objectives: This study aims to elucidate the relationship between red blood cell (RBC) count and D-dimer levels in patients with spinal cord injury, with the goal of identifying potential therapeutic targets for minimizing D-dimer levels.

Study Design: An observational, retrospective, cross-sectional, single center study.

Setting: Individuals with SCI (576 cases) admitted to a rehabilitation medicine department.

View Article and Find Full Text PDF

Hyperpolarized Xe MRI/MRS enables quantitative mapping of function in lung airspaces, membrane tissue, and red blood cells (RBCs) within the pulmonary capillaries. The RBC signal also exhibits cardiogenic oscillations that are reduced in pre-capillary pulmonary hypertension (PH). This effect is obscured in patients with concomitant defects in transfer from airspaces to RBCs, which increase RBC oscillation amplitudes.

View Article and Find Full Text PDF

A Rare Case of Anomalous Pulmonary Venous Return.

Echocardiography

January 2025

Department of Ultrasound, Wuhan Asia Heart Hospital Affiliated to Wuhan University of Science and Technology, Wuhan Clinical Medical Research Center of Cardiovascular Imaging, Wuhan, China.

This manuscript presents a rare case of a complex pulmonary venous malposition with an intact atrial septum and ventricular septum. The study demonstrates the diagnostic utility of echocardiography and computed tomography in the evaluation of complex congenital heart disease.

View Article and Find Full Text PDF

Case: An active healthy 68-year-old male sustained a bilateral quadriceps tendon rupture while running. He underwent a simultaneous bilateral quadriceps tendon repair in a dual-surgeon approach. The right quadriceps tendon was repaired with a tourniquet, while the left quadriceps tendon tear was repaired without one.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!