Optimized extrusion melt-blending of polylactic acid (PLA) polymer with a minor biopolymeric phase, polybutylene adipate terephthalate (PBAT), and compatibilized with random ethylene-methyl acrylate-glycidyl methacrylate terpolymer (EMA-GMA, Trademark: Lotader AX-8900) led to an outstanding improvement in mechanical properties. At the noncompatibilized PLA-PBAT (80-20) blend point, significant enhancement (∼4500%) in toughness and elongation-at-break was already obtained without compromising any elastic properties. The effect of the compatibilizer content on the mechanical properties of the PLA-PBAT (80-20) blend was investigated by an optimal custom response surface methodology. Thus, 2 wt % Lotader content was determined to be optimal by a numerical optimization methodology with a desirability value, , of 0.882 to maximize toughness and elongation-at-break. The compatibilization and thermal behavior of the Lotader-modified blends were analyzed by scanning electron microscopy (SEM), differential scanning calorimetry (DSC), and thermogravimetric analysis (TGA). Upon adding the compatibilizer, the original phase-separated morphology of the blends changed from PBAT quasi-spherical domains to nearly elongated elliptical ones. It was also found that the interfacial boundary line of the domains faded away, which revealed that interfacial compatibility was achieved. The thermostability of the blends remained largely unaltered following the incorporation of PBAT and Lotader. Moreover, while PBAT exhibited a minor influence on the crystallinity of PLA, Lotader had no discernible impact on crystallinity, as evidenced by the DSC thermograms. Thus, the compatibilizer at the optimal point in the optimized blend ratio led to the formation of a phase-separated morphology that combined internal cavitation, interfacial cavitation, and strong adhesion features at the right proportions in the microstructure which underlies the micromechanisms driving the remarkable enhancement of as much as 7100% in toughness and ductility.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1021/acsami.4c06452 | DOI Listing |
Nanotechnology
January 2025
Universiti Teknologi PETRONAS, Centre of Innovative Nanostructures and Nanodevices (COINN), Universiti Teknologi PETRONAS, 32610 Seri Iskandar, Perak Darul Ridzuan, MALAYSIA, Seri Iskandar, Perak, 32610, MALAYSIA.
Most previously reported susceptors for microwave welding are in powder form. In this study, a thin-film susceptor was employed due to its uniform heating rate and ease of handling. Silicon carbide nanowhisker (SiCNW) were incorporated into a poly(methyl methacrylate) (PMMA) matrix to create a nanocomposite thin film, which served as the susceptor.
View Article and Find Full Text PDFTransl Vis Sci Technol
December 2024
Department of Biomedical Engineering, University of Houston, Houston, TX, USA.
Purpose: To assess the safety of acoustic radiation force optical coherence elastography in the crystalline lens in situ.
Methods: Acoustic radiation force (ARF) produced by an immersion single-element ultrasound transducer (nominal frequency = 3.5 MHz) was characterized using a needle hydrophone and used for optical coherence elastography (OCE) of the crystalline lens.
FASEB J
January 2025
Department of Orthopaedic Surgery, Washington University School of Medicine, St. Louis, Missouri, USA.
Osteoarthritis (OA) is characterized by articular cartilage degeneration, leading to pain and loss of joint function. Recent studies have demonstrated that omega-3 (ω3) polyunsaturated fatty acid (PUFA) supplementation can decrease injury-induced OA progression in mice fed a high-fat diet. Furthermore, PUFAs have been shown to influence the mechanical properties of chondrocyte membranes, suggesting that alterations in mechanosensitive ion channel signaling could contribute to the mechanism by which ω3 PUFAs decreased OA pathogenesis.
View Article and Find Full Text PDFBackground: Magnetic resonance elastography (MRE) is an MRI technique that uses mild, externally applied vibrations to quantify the mechanical properties of tissues in vivo. MRE measures, such as stiffness, have been shown to be sensitive to changes in brain health with aging and neurodegeneration. Here we used MRE to characterize differences in brain mechanical properties between individuals with amnestic mild cognitive impairment (aMCI) and cognitively unimpaired subjects (CU).
View Article and Find Full Text PDFProc Inst Mech Eng H
January 2025
Department of Mechanical Engineering, Chandigarh University, Mohali, Punjab, India.
Bone is a highly heterogeneous and anisotropic material with a hierarchical structure. The effect of diaphysis locations and directions of loading on elastic-plastic compressive properties of bovine femoral cortical bone was examined in this study. The impact of location and loading directions on elastic-plastic compressive properties of cortical bone was found to be statistically insignificant in this study.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!