Patient-specific closed-loop model of the fontan circulation: Calibration and validation.

Heliyon

School of Biomedical Engineering and Imaging Sciences, King's College London, St Thomas' Hospital, SE1 7EH, London, UK.

Published: May 2024

The Fontan circulation, designed for managing patients with a single functional ventricle, presents challenges in long-term outcomes. Computational methods offer potential solutions, yet their application in cardiology practice remains largely unexplored. Our aim was to assess the ability of a patient-specific, closed-loop, reduced-order blood flow model to simulate pulsatile blood flow in the Fontan circulation. Using one-dimensional models, we simulated the aorta, superior and inferior venae cavae, and right and left pulmonary arteries, while lumping heart chambers and remaining vessels into zero-dimensional models. The model was calibrated with patient-specific haemodynamic data from combined cardiac catheterisation and magnetic resonance exams, using a novel physics-based stepwise methodology involving simpler open-loop models. Testing on a 10-year-old, anesthetised patient, demonstrated the model's capability to replicate pulsatile pressure and flow in the larger vessels and ventricular pressure. Average relative errors in mean pressure and flow were 2.9 % and 3.6 %, with average relative point-to-point errors (RPPE) in pressure and flow at 5.2 % and 16.0 %. Comparing simulation results to measurements, mean aortic pressure and flow values were 50.7 vs. 50.4 mmHg and 41.6 vs. 41.9 ml/s, respectively, while ventricular pressure values were 28.7 vs. 27.4 mmHg. The model accurately described time-varying ventricular volume with a RPPE of 2.9 %, with mean, minimum, and maximum ventricular volume values for simulation results vs. measurements at 59.2 vs. 58.2 ml, 38.0 vs. 37.6 ml, and 76.0 vs. 74.4 ml, respectively. It provided physiologically realistic predictions of haemodynamic changes from pulmonary vasodilation and atrial fenestration opening. The new model and calibration methodology are freely available, offering a platform to virtually investigate the Fontan circulation's response to clinical interventions and explore potential mechanisms of Fontan failure. Future efforts will concentrate on broadening the model's applicability to a wider range of patient populations and clinical scenarios, as well as testing its effectiveness.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11089314PMC
http://dx.doi.org/10.1016/j.heliyon.2024.e30404DOI Listing

Publication Analysis

Top Keywords

pressure flow
16
fontan circulation
12
patient-specific closed-loop
8
blood flow
8
ventricular pressure
8
average relative
8
simulation measurements
8
ventricular volume
8
flow
6
pressure
6

Similar Publications

Background And Aims: Ward-delivered non-invasive respiratory supports (NIRS) (conventional oxygen therapy (COT), high-flow nasal oxygen (HFNO), continuous positive airway pressure (CPAP) and non-invasive ventilation (NIV)), are often used to treat hospitalised patients with acute respiratory failure (ARF) both in high acuity and general wards. This study aimed to describe the processes of care adopted and examine patient outcomes from a specialist, ward-delivered NIRS service caring for people with COVID-19 in general wards or in a respiratory care unit (RCU).

Methods: A cohort study was undertaken including all consecutive patients admitted to a quaternary hospital with ARF secondary to COVID-19 and requiring ward-delivered NIRS between 28 February 2020 and 18 March 2022.

View Article and Find Full Text PDF

Advancement of the Dragon Heart 7-Series for Pediatric Patients With Heart Failure.

Artif Organs

January 2025

BioCirc Research Laboratory, School of Biomedical Engineering, Science, and Health Systems, Drexel University, Philadelphia, Pennsylvania, USA.

Background: Safe and effective pediatric blood pumps continue to lag far behind those developed for adults. To address this growing unmet clinical need, we are developing a hybrid, continuous-flow, magnetically levitated, pediatric total artificial heart (TAH). Our hybrid TAH design, the Dragon Heart (DH), integrates both an axial flow and centrifugal flow blood pump within a single, compact housing.

View Article and Find Full Text PDF

: Sinus lifting, a procedure to augment bone in the maxilla, may cause complications such as sinusitis due to impaired drainage. This study aimed to assess how sinus lifting impacts airflow in the sinus cavity, which is essential for patients undergoing dental implants. Using computational fluid dynamics (CFD), this research analyzed airflow changes after sinus floor elevation, offering insights into the aerodynamic consequences of the procedure.

View Article and Find Full Text PDF

Background: There is compelling evidence of an inverse association between potassium intake and blood pressure (BP). A potential mechanism for this effect may be dietary potassium-mediated augmentation of endothelium-dependent relaxation. To date, studies have investigated potassium intake supplementation over several weeks in healthy volunteers with variable results on vascular function.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!