This radiobiological investigation was based on measurements of crypt cell survival in mouse small intestine when the animals were exposed to 5 cm3 (spot), 350 cm3 and 3010 cm3 (the latter two were spot scans) pion stopping volumes generated by the multi-channel Piotron of the Swiss Institute for Nuclear Research. The experimental data obtained indicate that there was a decrease in biological effectiveness when the pion treatment volume was enlarged, irrespective of whether the pion dose was delivered in a single exposure or in four fractions. The r.b.e. values for pion beams relative to 200 kVp X-rays for the different experimental conditions used in this study are presented. The phenomenon of decreasing biological effectiveness with increasing pion stopping volume may be attributed to the following two factors: (1) when the pion stopping volume is increased there is a corresponding dilution of the high l.e.t. component of the beam; (2) the biological test system used may be sensitive to radiation dose rate which varied by a ratio of about 20 for the pion volumes used in this study.

Download full-text PDF

Source
http://dx.doi.org/10.1080/09553008514551071DOI Listing

Publication Analysis

Top Keywords

pion stopping
16
pion
8
stopping volumes
8
mouse small
8
small intestine
8
cm3 spot
8
biological effectiveness
8
stopping volume
8
volumes radiation
4
radiation response
4

Similar Publications

Purpose: Characterization of soft tissue, water and air in terms of effective atomic number (Z) with respect to the interactions of hadrons, leptons and isotopes of hydrogen.

Method: Mass collision stopping powers (MCSPs) were calculated first using Bethe formula. Then, these values were used to estimate Z using linear-logarithmic interpolation.

View Article and Find Full Text PDF

At the Mainz Microtron MAMI, the first high-resolution pion spectroscopy from decays of strange systems was performed by electron scattering off a (9)Be target in order to study the Λ binding energy of light hypernuclei. Positively charged kaons were detected by a short-orbit spectrometer with a broad momentum acceptance at 0° forward angles with respect to the beam, efficiently tagging the production of strangeness in the target nucleus. Coincidentally, negatively charged decay pions were detected by two independent high-resolution spectrometers.

View Article and Find Full Text PDF

Particles originating from primary cosmic radiation, which hit the Earth's atmosphere give rise to a complex field of secondary particles. These particles include neutrons, protons, muons, pions, etc. Since the 1980s it has been known that terrestrial cosmic rays can penetrate the natural shielding of buildings, equipment and circuit package and induce soft errors in integrated circuits.

View Article and Find Full Text PDF

Radiation therapy using antiprotons is a potential interesting future modality. Energetic antiprotons penetrate matter with almost near identical stopping powers and radio biological effectiveness (RBE) as protons in the region well before the Bragg peak region. When the antiprotons come to rest at or near the Bragg peak, they annihilate releasing almost 2 GeV per annihilation.

View Article and Find Full Text PDF

The first observation of the kaonic (3)He 3d→2p transition was made, using slow K- mesons stopped in a gaseous (3)He target. The kaonic atom X-rays were detected with large-area silicon drift detectors using the timing information of the K+K- pairs of ϕ-meson decays produced by the DAΦNE e+e- collider. The strong interaction shift of the kaonic (3)He 2p state was determined to be -2±2(stat)±4(syst) eV.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!