Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Purpose: This study aimed to evaluate the accuracy of 12 intraocular lens (IOL) power calculation formulae for eyes that have undergone both radial keratotomy (RK) and laser assisted in situ keratomileusis (LASIK) surgery to determine the efficacy of various IOL calculations for this unique patient group. Currently, research on this surgical topic is limited.
Methods: In this retrospective study, 11 eyes from 7 individuals with a history of RK and LASIK who underwent cataract surgery at Hoopes Vision were analyzed. Preoperative biometric and corneal topographic measurements were performed. Subjective refraction was obtained postoperatively. Twelve different intraocular lens (IOL) power calculations were used: Barrett True K No History, Barrett True K (prior LASIK, Prior RK history), Barrett Universal 2, Camellin-Calossi-Camellin (3C), Double K-Modified Holladay, Haigis-L, Galilei, OCT, PEARL-DGS, Potvin-Hill, Panacea, and Shammas.
Results: The rankings of mean arithmetic error (MAE), from least to greatest, were as follows: 3C (0.088), Haigis-L-L (-0.508), Shammas (-0.516), OCT Average (-0.538), Barrett True K (-0.557), OCT RK (-0.563), Galilei (-0.570), IOL Master (-0.571), OCT LASIK (-0.583), Barrett True K No History (-0.597), Pearl-DGS (-0.606), Potvin-Hill SF (-0.770), Potvin-Hill TNP (-0.778), Panacea (-0.876), and Barrett Universal 2 (-1.522). The 3C formula achieved the greatest percentage of eyes within ±0.25 D of target range (91%), while Haigis-L, Shammas, Galilei, Potvin Hill, Barrett True K, IOL Master, PEARL-DGS, and OCT formulae performed similarly, achieving 45% of eyes within ±0.75D of target refraction.
Conclusion: This study demonstrates the accuracy of the lesser known 3C formula in IOL calculation, particularly for patients who have undergone both RK and LASIK. Well-known formulae, such as Haigis-L, Shammas, and Galilei, which are used by the American Society of Cataract and Refractive Surgery (ASCRS), are viable options, although 3C formulae should be considered in this patient population. Furthermore, larger studies can confirm the best IOL power formulas for post-RK and LASIK cataract patients.