Objective: To evaluate the prediction performance of E-Cervix™ for preterm birth in twin pregnancies with threatened preterm labor.

Methods: This was a single-center retrospective cohort study of twin pregnancies presenting to obstetrics triage for threatened preterm labor (PTL) between 23 0/7 - 33 6/7 weeks who received screening for PTL with transvaginal ultrasound cervical length (TVU CL) and cervical elastography with E-Cervix™ at the time of triage. Cervical elastography parameters were examined and compared between women who delivered preterm and those who did not. The quantification of cervical strain was calculated by a data analysis system that directly analyzes raw data from the region of interest (ROI) and described as hardness ratio (HR), mean strain level within 1 cm from internal (IOS) and external (EOS) os.

Results: 63 twin gestations without prior preterm birth and with threatened PTL between 23 0/7 - 33 6/7 weeks of gestation were included in the study. 27 (42.9 %) had cervical length < 25 mm, and were admitted for true PLT. Out of the 36 women with cervical length ≥ 25 mm, 6 (16.7 %) were admitted. Women with threatened PTL had significantly higher HR compared to those with true PTL (p < 0.01), and significantly lower IOS and EOS. Women who delivered preterm had significantly higher HR compared to those who did not delivery preterm and significantly lower IOS and EOS, in overall cohort, and in the subset of women with true PTL. Incidences of HR < 50 % and < 35 % were statistically significantly higher in women who delivered preterm compared to those who did not (p < 0.01).

Conclusion: Cervical elastography with E-Cervix™ may be useful for assessment of twin gestations presenting to obstetrics triage for threatened PTL.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ejogrb.2024.05.001DOI Listing

Publication Analysis

Top Keywords

cervical elastography
12
preterm birth
12
twin pregnancies
12
threatened preterm
12
elastography e-cervix™
8
birth twin
8
pregnancies threatened
8
preterm labor
8
ptl 0/7
8
0/7 6/7
8

Similar Publications

Objectives: To compare the values of ultrasound and clinical parameters for predicting outcomes of induction of labor (IOL) among healthy nulliparous women with a singleton, term cephalic pregnancy.

Methods: The cervical length, cervical strain elastography, posterior cervical angle, head-perineum distance, Bishop score, and maternal parameters were assessed before IOL with a combined method-Foley catheter and Misoprostol perorally. The main outcome was vaginal delivery.

View Article and Find Full Text PDF

The Emerging Role of Sonoelastography in Pregnancy: Applications in Assessing Maternal and Fetal Health.

Diagnostics (Basel)

December 2024

Radiology and Medical Imaging Department, College of Applied Medical Sciences, Prince Sattam bin Abdulaziz University, Al-Kharj 16278, Saudi Arabia.

Sonoelastography, a novel ultrasound-based technique, is emerging as a valuable tool in prenatal diagnostics by quantifying tissue elasticity and stiffness in vivo. This narrative review explores the application of sonoelastography in assessing maternal and fetal health, with a focus on cervical, placental, pelvic floor, and fetal tissue evaluations. In the cervix, sonoelastography aids in predicting preterm birth and assessing labor induction success.

View Article and Find Full Text PDF

Introduction: Increased muscle stiffness in the upper trapezius has been suggested to be associated with cervical myofascial pain and myofascial trigger points (MTrP). Recently, efforts have been made to objectively detect MTrP using ultrasound shear wave elastography (SWE). However, there is no consensus on the relationship between muscle stiffness assessed by SWE and MTrP.

View Article and Find Full Text PDF

To evaluate the predictive effect of transvaginal ultrasound measurement of cervical length and cervical elasticity examination on cervical insufficiency in twin pregnancies. Data from twin pregnant women in our hospital were collected retrospectively, including relevant vaginal ultrasound parameters (e.g.

View Article and Find Full Text PDF
Article Synopsis
  • Preterm delivery significantly contributes to neonatal deaths and long-term health issues, presenting a major global health challenge, with cervical elastography emerging as a promising diagnostic tool for predicting such deliveries.
  • The study assessed the effectiveness of transvaginal strain cervical elastography in predicting preterm delivery among 75 low-risk, asymptomatic women, utilizing ultrasound to analyze cervical length and strain data.
  • Findings revealed that a red color sign at the anterior lip of the cervix was a strong predictor of preterm delivery, alongside additional indicators like an elastography strain ratio greater than 2 and a cervical length of 2.8 cm or less.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!