A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

[Colorectal cancer screening with virtual colonography]. | LitMetric

[Colorectal cancer screening with virtual colonography].

Radiologie (Heidelb)

Zentrum für Radiologie, Neuroradiologie und Nuklearmedizin, Clemenshospital und Raphaelsklinik, Münster, Deutschland.

Published: June 2024

Background: Since 2003, a decline in the age-standardized incidence rates of colorectal cancer (CRC) has been observed in Germany. Nonetheless, one in eight cancer cases still affects the colon or rectum. The prognosis has improved, with the relative 5‑year survival rate for CRC being approximately 65%.

Methods: This positive trend is probably a result of preventive measures introduced over the last 20 years. This could be further improved, however, as CRC can not only be detected early but in almost all cases also prevented through the identification of benign precursors. Less than half of all eligible individuals participate in screening via colonoscopy. This implies that further, possibly even imaging, screening test methods should be explored and offered. Studies have reported that virtual colonography techniques have a comparable accuracy to endoscopy of about 90% for polyp sizes larger than 5 mm. The data for computed tomography (CT) is more extensive than for magnetic resonance imaging (MRI).

Conclusion: Significant challenges are posed however by the fact that in Germany CT colonography (CTC) is not considered a viable screening option due to radiation protection concerns, and MRI screening is not an established screening method. Radiologists should be familiar with classification using the CT Colonography Reporting and Data System (C-RADS), which uses criteria such as CT density, morphology, size, and location for classification. C‑RADS classification follows the categories: C0 (inadequate study), C1 (normal), C2a (indeterminate), C2b (benign), C3 (suspicious), and C4 (malignant), as well as extracolonic categories E1/2 (no clinically significant findings), E3 (likely insignificant findings), and E4 (likely significant findings).

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00117-024-01321-0DOI Listing

Publication Analysis

Top Keywords

screening
6
[colorectal cancer
4
cancer screening
4
screening virtual
4
virtual colonography]
4
colonography] background
4
background 2003
4
2003 a decline
4
a decline age-standardized
4
age-standardized incidence
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!