Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
The applications of organic-amine desulfurization have steadily increased owing to its high efficiency, low cost, and low energy consumption. Different proportions of organic amines exert different effects on sulfur dioxide removal. Therefore, the accurate determination of different organic amines in the desulfurization solution is of great importance. The ion-chromatographic method for the detection of organic amines does not require a derivatization step, has simple pretreatment procedures, and allows for the simultaneous determination of many types of organic amines. In this study, a method based on ion chromatography was developed for the simultaneous determination of ethanolamine (MEA), diethylethanolamine (DEEA), -methyldiethanolamine (MDEA), 2-amino-2-methyl-1-propanol (AMP), hydroxyethylethylenediamine (AEEA), piperazine (PZ), -hydroxyethylpiperazine (HEPZ), and diethylenetriamine (DETA). The separation efficiency of the eight organic amines in different types of columns, leaching solutions, and column temperatures were compared. The determination was performed using an IonPac CS17 column with column temperature of 35 ℃ and gradient leaching with methyl sulfonic acid (MSA) solution via the inhibition conductance method. Samples of the desulfurization solution were analyzed using ultrapure water filtered through a 0.22 μm nylon microporous filter membrane and an OnGuard Ⅱ RP column; thus, the pretreatment steps are simple. The eight organic amines showed a good linear relationship within a certain concentration range, and the coefficient of determinations () were greater than 0.998. The limits of detection (LODs) and quantification (LOQs) were determined from the mass concentrations of the organic amines corresponding to signal-to-noise ratios () of 3 and 10, respectively. LODs of 0.02-0.08 mg/L and LOQs of 0.07-0.27 mg/L were determined from a 1.0 μL sample injection. The actual recoveries ranged from 93.0% to 111%, and the relative standard deviations (RSDs, =5) ranged from 0.31% to 1.2%. The results indicated that the proposed method has good accuracy and precision; thus, it is suitable for the determination of various organic amines in desulfurization solution.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11089448 | PMC |
http://dx.doi.org/10.3724/SP.J.1123.2023.09024 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!