Cumulative sum learning curve for cordocentesis among maternal-fetal medicine fellows in a low-cost simulation model.

Int J Gynaecol Obstet

Department of Maternal and Fetal Medicine, Instituto Nacional de Perinatologia, Mexico City, Mexico.

Published: November 2024

Objective: To determine the individual learning curves for cordocentesis in a low-cost simulator for maternal-fetal medicine (MFM) fellows.

Methods: This observational, descriptive, educational, and prospective study was performed from July through November 2022. After an introductory course based on a standardized technique for cordocentesis, each second-year MFM fellow who accepted to participate in the study performed this procedure using a low-cost simulation model, and experienced operators supervised the cordocenteses. Learning curves were then created using cumulative sum analysis (CUSUM).

Results: Seven second-year MFM fellows with no previous experience in cordocentesis accepted to participate in the study. A total of 2676 procedures were assessed. On average, residents performed 382 ± 70 procedures. The mean number of procedures to achieve proficiency was 369 ± 70, the overall success rate was 84.16%, and the corresponding failure rate was 15.84%. At the end of the study, all fellows were considered competent in cordocentesis. One fellow required 466 attempts to achieve competency, performing a total of 478 procedures, but the resident with the fewest attempts to reach competency required 219 procedures, completing 232 procedures. Some of the most frequent reasons for failed attempts included not reaching the indicated point for vascular access (20.99%) and being unable to retrieve the sample (69.10%).

Conclusion: CUSUM analysis to assess learning curves, in addition to using low-cost simulation models, helped to appraise individualized learning, allowing an objective demonstration of competency for cordocentesis among MFM fellows.

Download full-text PDF

Source
http://dx.doi.org/10.1002/ijgo.15611DOI Listing

Publication Analysis

Top Keywords

low-cost simulation
12
learning curves
12
cumulative sum
8
maternal-fetal medicine
8
simulation model
8
study performed
8
second-year mfm
8
accepted participate
8
participate study
8
mfm fellows
8

Similar Publications

In otolaryngology, training often involves simulation in animal specimens, human cadavers, and artificial models to facilitate learning surgical procedures, reducing the time needed to acquire essential skills. Simulated training has become integral to medical education, particularly in microsurgical techniques, such as microlaryngeal surgery. These procedures, also known as phonomicrosurgery, are performed on the vocal folds using microscopic visualization and precision instruments with long shafts and millimetric tips.

View Article and Find Full Text PDF

The increasing use of recreational nitrous oxide ([Formula: see text]O) in the Netherlands and its link to traffic accidents highlights the need for reliable detection methods for law enforcement. This study focused on ex vivo detection of [Formula: see text]O in exhaled breath and examining its persistence in the human body. Firstly, a low-cost portable infrared based detector was selected and validated to detect [Formula: see text]O in air.

View Article and Find Full Text PDF

The angle of polarized light (AOP) property for optical classification of the crosslinked polymer.

Spectrochim Acta A Mol Biomol Spectrosc

December 2024

Department of Biomedical Engineering, Faculty of Engineering, Universiti Malaya, Federal Territory of Kuala Lumpur, Kuala Lumpur 50603 Malaysia.

Light-matter interaction has been profoundly studied for sample material classification. However, the optical classification of the sample through the polarized light-matter interaction remains underexplored. It is limited to the measurement of intensity instead of the angle of polarized light (AOP) for its degree of polarization.

View Article and Find Full Text PDF

Molten Sn solvent expands liquid metal catalysis.

Nat Commun

January 2025

School of Chemical and Biomolecular Engineering, The University of Sydney, Sydney, Australia.

Regulating favorable assemblies of metallic atoms in the liquid state provides promise for catalyzing various chemical reactions. Expanding the selection of metallic solvents, especially those with unique properties and low cost, enables access to distinctive fluidic atomic structures on the surface of liquid alloys and offers economic feasibility. Here, Sn solvent, as a low-cost commodity, supports unique atomic assemblies at the interface of molten SnInCu, which are highly selective for H synthesis from hydrocarbons.

View Article and Find Full Text PDF

Can a Cochlear Implant Be Used as an Electrical Impedance Tomography Device?

Int J Numer Method Biomed Eng

January 2025

Bioengineering, Department of Electrical, Electronic and Computer Engineering, University of Pretoria, Gauteng, South Africa.

The imaging of the live cochlea is a challenging task. Regardless of the quality of images obtained from modern clinical imaging techniques, the internal structures of the cochlea mainly remain obscured. Electrical impedance tomography (EIT) is a safe, low-cost alternative medical imaging technique with applications in various clinical scenarios.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?