Recently, carbon fiber (CF) has prevailed as the primary material used in radiotherapy couchtops. Modern couchtops incorporate the CF sandwich design, in which 2 thin CF plates sandwich an air-equivalent polymeric foam. Developments in radiotherapy necessitate irradiation from posterior angles through the couchtop. However, the presence of the couchtop needs proper modeling in the treatment planning system (TPS) due to attenuation; otherwise, the tumor dose is reduced. In the current study, an effort was made with the intent of finding the optimum electron density (ED) values for Elekta's iBEAM Evo couchtop components (CF and Foam Core (FC)) for its proper modeling in Monaco TPS. Also, the attenuation of the beam due to the couchtop's presence was investigated. A cylindrical phantom with an ionization chamber positioned at the isocenter was utilized for the measurements. The phantom was placed centrally on the iBEAM Evo couchtop and was irradiated with an Elekta Infinity linear accelerator's 6, 10, and 15 MV photon beams. The gantry angle was set at 0 and from 120 to 180 with an increment of 10. The same procedure was designed and followed in Monaco TPS. Measured and calculated dose values were compared by calculating percentage deviation (PD). Attenuation has also been calculated using the measurements of the experimental setup and the Monaco calculations. The values of ED that provided the optimum agreement between measured and Monaco-calculated dose values while minimizing PD were 0.55 g/cm for CF, and 0.1 g/cm for FC. The maximum values of PD for the beams of 6, 10, and 15 MV were -0.62%, +1,78%, and +2.35%, respectively, for a 5 × 5 cm field size. Furthermore, Monaco predicted attenuation from 1.83% to 6.26% (calculated values), while from the measurements, an attenuation from 1.44% to 5.75% (measured values) regarding the posterior angles was found. Thus, good agreement was verified between the TPS calculations and experimental measurements. Elekta's iBEAM Evo couchtop modeling was successfully validated in Monaco TPS. The couchtop's presence alters the patient's dose regarding irradiation from the posterior angles. Due to the attenuation of the beam, proper incorporation, modeling, and validation of the couchtop are necessary to improve the radiotherapy outcome and ensure that each patient receives the optimal treatment.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.meddos.2024.04.004DOI Listing

Publication Analysis

Top Keywords

ibeam evo
16
evo couchtop
16
posterior angles
12
monaco tps
12
couchtop modeling
8
modeling monaco
8
treatment planning
8
planning system
8
irradiation posterior
8
proper modeling
8

Similar Publications

Recently, carbon fiber (CF) has prevailed as the primary material used in radiotherapy couchtops. Modern couchtops incorporate the CF sandwich design, in which 2 thin CF plates sandwich an air-equivalent polymeric foam. Developments in radiotherapy necessitate irradiation from posterior angles through the couchtop.

View Article and Find Full Text PDF

Commissioning of a RayStation structure template for the iBEAM evo Couchtop.

Phys Eng Sci Med

December 2023

South Western Sydney Cancer Services, Sydney, Australia.

Accurate radiotherapy treatment planning requires attenuation through the treatment couch to be accounted for in dose calculation. This is commonly performed by using contouring tools to add a virtual structure in the shape of the treatment couch and assigning the preferred absorption properties. The RayStation treatment planning system (TPS) allows users to assign a material that comprises both an elemental structure and a physical density.

View Article and Find Full Text PDF

The use of Monte Carlo treatment planning systems (TPS) in radiation therapy has increased the dosimetric accuracy of VMAT treatment sequences. However, this accuracy is compromised by not including the treatment couch into the treatment planning process. Therefore, the impact of the treatment couch on radiation delivery output was determined, and two different couch models (uniform couch model A vs two components model B) were included and tested in the Monaco TPS to investigate which model can better quantify the couch influence on radiation dose.

View Article and Find Full Text PDF

This study is to demonstrate the importance and a method of properly modeling the treatment couch for dose calculation in patient treatment using arc therapy. The 2 treatment couch tops-Aktina AK550 and Elekta iBEAM evo-of Elekta LINACs were scanned using Philips Brilliance Big Bore CT Simulator. Various parts of the couch tops were contoured, and their densities were measured and recorded on the Pinnacle treatment planning system (TPS) using the established computed tomography density table.

View Article and Find Full Text PDF

Noncoplanar radiation fields from a linear accelerator can be used to deliver radiation dose distributions that are superior to those delivered using coplanar radiation fields. Noncoplanar radiation field arrangements are especially valuable when delivering stereotactic body radiation therapy (SBRT). Noncoplanar radiation fields, however, are geometrically more challenging to deliver than coplanar radiation fields, and are associated with a greater risk of collisions between the gantry, treatment couch, and patient.

View Article and Find Full Text PDF