Collared Cementless Femoral Components Reduce the Revision Rates in Primary Total Hip Arthroplasty Using the Direct Anterior Approach: An Australian Orthopaedic Association National Joint Replacement Registry Study.

J Arthroplasty

Department of Surgery, The University of Melbourne, Eastern Hill Campus, Fitzroy, Victoria, Australia; Department of Orthopaedics, St Vincent's Hospital Melbourne, Fitzroy, Victoria, Australia; Victorian Bone and Joint Specialists, Fitzroy, Victoria, Australia.

Published: September 2024

Background: An increased risk of periprosthetic fracture and aseptic loosening is reported when the direct anterior approach (DAA) is used for total hip arthroplasty (THA), especially with cementless implants. We assessed the rate of revision comparing collared and collarless femoral stems when using the DAA for THA.

Methods: We used data from the Australian Orthopaedic Association National Joint Replacement Registry for primary THA for osteoarthritis inserted with the DAA between January 2015 and December 2022. There were 48,567 THAs that used the DAA (26,690 collarless cementless, 10,161 collared cementless, and 11,716 cemented). Cumulative percent revision was calculated for all-cause revision, revision for periprosthetic femoral fractures, and aseptic femoral stem loosening. Cox proportional hazard ratios [HRs] were used to compare the revision of collared and collarless cementless stems. We also compared collared cementless stems and cemented stems.

Results: A higher rate of all-cause revision within 3 months of surgery was observed with collarless compared to collared cementless implants (HR: 1.99 [95% confidence interval (CI), 1.56 to 2.54]; P < .001). Similarly, collarless cementless implants were associated with a greater rate of revision for fracture in the first 6 months (HR: 2.90 [95% CI, 1.89 to 4.45]; P < .001) and after 6 months (HR 10.04 [95% CI 1.38 to 73.21]; P = .02), as well as an increased rate of revision for aseptic loosening after 2 years (HR: 5.76 [95% CI, 1.81 to 18.28], P = .003). Collared cementless and cemented stems performed similarly.

Conclusion: Collared stems were associated with a reduced rate of all-cause revision for cementless THA performed via the DAA. The reduction in risk may be due to protection from periprosthetic femoral fracture and aseptic loosening.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.arth.2024.05.009DOI Listing

Publication Analysis

Top Keywords

collared cementless
20
aseptic loosening
12
cementless implants
12
rate revision
12
collarless cementless
12
all-cause revision
12
revision
10
cementless
9
collared
8
total hip
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!