Surface acoustic waves (SAW) and associated devices are ideal for sensing, metrology, and hybrid quantum devices. While the advances demonstrated to date are largely based on electromechanical coupling, a robust and customizable coherent optical coupling would unlock mature and powerful cavity optomechanical control techniques and an efficient optical pathway for long-distance quantum links. Here we demonstrate direct and robust coherent optical coupling to Gaussian surface acoustic wave cavities with small mode volumes and high quality factors (>10 measured here) through a Brillouin-like optomechanical interaction. High-frequency SAW cavities designed with curved metallic acoustic reflectors deposited on crystalline substrates are efficiently optically accessed along piezo-active directions, as well as non-piezo-active (electromechanically inaccessible) directions. The precise optical technique uniquely enables controlled analysis of dissipation mechanisms as well as detailed transverse spatial mode spectroscopy. These advantages combined with simple fabrication, large power handling, and strong coupling to quantum systems make SAW optomechanical platforms particularly attractive for sensing, material science, and hybrid quantum systems.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11088653 | PMC |
http://dx.doi.org/10.1038/s41467-024-48167-7 | DOI Listing |
Retina
January 2025
Department of Ophthalmology, Kagoshima University Graduate School of Medical and Dental Sciences, Kagoshima, Japan.
Purpose: To identify optical coherence tomography (OCT)-based imaging biomarkers that can localize focal leakage points without fluorescein angiography in central serous chorioretinopathy (CSC).
Methods: This retrospective case-control study analyzed 119 consecutive patients (123 eyes) with CSC between April 2018 and February 2024, comprising 66 eyes with focal-leakage type and 57 eyes with diffuse-leakage type. We assessed leakage sites using OCT, and the proportions of OCT findings were compared between focal- and diffuse-leakage types.
Retin Cases Brief Rep
January 2025
Herbert Wertheim College of Medicine, Florida International University, Miami, Florida, USA.
Purpose: To report a case of drusen regression following pars plana vitrectomy with internal limiting membrane peel (ILMP) in a patient with a full-thickness macular hole and dry age-related macular degeneration (AMD).
Methods: A 67-year-old gentleman presented in April 2024 with a full-thickness macular hole in OS and intermediate dry AMD OU. The patient underwent pars plana vitrectomy, ILMP, and an injection of sulfur hexafluoride gas for macular hole repair in OS.
Purpose: Predicting long-term anatomical responses in neovascular age-related macular degeneration (nAMD) patients is critical for patient-specific management. This study validates a generative deep learning (DL) model to predict 12-month posttreatment optical coherence tomography (OCT) images and evaluates the impact of incorporating clinical data on predictive performance.
Methods: A total of 533 eyes from 513 treatment-naïve nAMD patients were analyzed.
Rev Sci Instrum
January 2025
Optics Research Group, Imaging Physics Department, Delft University of Technology, Van der Waalsweg 8, 2628 CH Delft, The Netherlands.
We demonstrate a broadband implementation of coherent Fourier scatterometry (CFS) using a supercontinuum source. Spectral information can be resolved by splitting the incident field into two pulses with a variable delay and interfering them at the detector after interaction with the sample, bearing similarities with Fourier-transform spectroscopy. By varying the time delay between the pulses, a collection of diffraction patterns is captured in the Fourier plane, thereby obtaining an interferogram for every camera pixel.
View Article and Find Full Text PDFBackground And Objective: Sickle cell disease (SCD) is a vascular disease that may affect the retina. This study aimed to evaluate differences in average velocity (AV, mm/s), blood flow (BF, μL/min) and vessel diameter (VD, μm) from the temporal retinal arcades in SCD compared to healthy eyes using Doppler optical coherence tomography (DOCT).
Patients And Methods: A cross-sectional study was conducted between 2021 and 2023.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!