Image Reconstruction Requirements for Short-Range Inductive Sensors Used in Single-Coil MIT.

Sensors (Basel)

Tayos Corp., 1816 Gallagher Ln, Louisville, CO 80027, USA.

Published: April 2024

MIT (magnetic induction tomography) image reconstruction from data acquired with a single, small inductive sensor has unique requirements not found in other imaging modalities. During the course of scanning over a target, measured inductive loss decreases rapidly with distance from the target boundary. Since inductive loss exists even at infinite separation due to losses internal to the sensor, all other measurements made in the vicinity of the target require subtraction of the infinite-separation loss. This is accomplished naturally by treating infinite-separation loss as an unknown. Furthermore, since contributions to inductive loss decline with greater depth into a conductive target, regularization penalties must be decreased with depth. A pair of squared L2 penalty norms are combined to form a 2-term Sobolev norm, including a zero-order penalty that penalizes solution departures from a default solution and a first-order penalty that promotes smoothness. While constraining the solution to be non-negative and bounded from above, the algorithm is used to perform image reconstruction on scan data obtained over a 4.3 cm thick phantom consisting of bone-like features embedded in agarose gel, with the latter having a nominal conductivity of 1.4 S/m.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11085655PMC
http://dx.doi.org/10.3390/s24092704DOI Listing

Publication Analysis

Top Keywords

image reconstruction
12
inductive loss
12
infinite-separation loss
8
inductive
5
loss
5
reconstruction requirements
4
requirements short-range
4
short-range inductive
4
inductive sensors
4
sensors single-coil
4

Similar Publications

. To develop an augmentation method that simulates cone-beam computed tomography (CBCT) related motion artifacts, which can be used to generate training-data to increase the performance of artificial intelligence models dedicated to auto-contouring tasks.The augmentation technique generates data that simulates artifacts typically present in CBCT imaging.

View Article and Find Full Text PDF

Significance: Protoporphyrin IX (PpIX) delayed fluorescence (DF) is inversely related to the oxygen present in tissues and has potential as a novel biomarker for surgical guidance and real-time tissue metabolism assessment. Despite the unique promise of this technique, its successful clinical translation is limited by the low intensity emitted.

Aim: We developed a systematic study of ways to increase the PpIX DF signal through acquisition sampling changes, allowing optimized imaging at video rates.

View Article and Find Full Text PDF

We describe a novel application of photon-counting detector CT (PCD-CT) in neurovascular imaging by harnessing the improved spatial resolution, attenuation of electronic noise, and reduction of metal artifacts. The presented case offers the unique challenge of high-quality imaging for the assessment of treated and untreated intracranial saccular aneurysms, in the setting of metal artifacts from embolization coils. Our goal was to explore optimized reconstruction parameters for ultra-high-resolution imaging (UHR) using a dedicated, sharp neurovascular kernel (Hv72) and the highest strength of quantum iterative reconstruction (QIR-4) for detailed characterization of the vasculature.

View Article and Find Full Text PDF

True total-body and extended axial field-of-view (AFOV) PET/CT with 1m or more of body coverage are now commercially available and dramatically increase system sensitivity over conventional AFOV PET/CT. The Siemens Biograph Vision Quadra (Quadra), with an AFOV of 106cm, potentially allows use of significantly lower administered radiopharmaceuticals as well as reduced scan times. The aim of this study was to optimise acquisition protocols for routine clinical imaging with FDG on the Quadra the prioritisation of reduced activity given physical infrastructure constraints in our facility.

View Article and Find Full Text PDF

Much evidence suggests that the choroid plexus (CP) plays an important role in the pathophysiology of systemic lupus erythematosus (SLE), but its imaging profile in neuropsychiatric SLE (NPSLE) remains unexplored. To evaluate CP volume in NPSLE patients using MRI. This retrospective study evaluated patients with SLE who underwent MRI of the brain, including three-dimensional T1-weighted imaging.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!