Purpose: To compare the accuracy of the Microsoft Kinect V2 with novel pose estimation frameworks, in assessing knee kinematics during athletic stress tests, for fast and portable risk assessment of anterior cruciate ligament (ACL) injury.
Methods: We captured 254 varsity athletes, using the Kinect V2 and a smartphone application utilizing Google's MediaPipe framework. The devices were placed as close as possible and used to capture a person, facing the cameras, performing one of three athletic stress tests at a distance of 2.5 ms. Custom software translated the results from both frameworks to the same format. We then extracted relevant knee angles at key moments of the jump and compared them, using the Kinect V2 as the ground truth.
Results: The results show relatively small angle differences between the two solutions in the coronal plane and moderate angle differences on the sagittal plane. Overall, the MediaPipe framework results seem to underestimate both knee valgus angles and knee sagittal angles compared to the Kinect V2.
Conclusion: This preliminary study demonstrates the potential for Google's MediaPipe framework to be used for calculating lower limb kinematics during athletic stress test motions, which can run on most modern smartphones, as it produces similar results to the Kinect V2. A smartphone application similar to the one developed could potentially be used for low cost and widespread ACL injury prevention.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s11548-024-03156-5 | DOI Listing |
J Nanobiotechnology
January 2025
State Key Laboratory of Pharmaceutical Biotechnology, Division of Sports Medicine and Adult Reconstructive Surgery, Department of Orthopedic Surgery, Nanjing Drum Tower Hospital, The Affiliated Hospital of Nanjing University Medical School, 321 Zhongshan Road, Nanjing, 210008, People's Republic of China.
RNA interference (RNAi) and oxidative stress inhibition therapeutic strategies have been extensively utilized in the treatment of osteoarthritis (OA), the most prevalent degenerative joint disease. However, the synergistic effects of these approaches on attenuating OA progression remain largely unexplored. In this study, matrix metalloproteinase-13 siRNA (siMMP-13) was incorporated onto polyethylenimine (PEI)-polyethylene glycol (PEG) modified FeO nanoparticles, forming a nucleic acid nanocarrier termed si-Fe NPs.
View Article and Find Full Text PDFMed Biol Eng Comput
January 2025
Auckland Bioengineering Institute, The University of Auckland, Auckland, New Zealand.
Lower limb biomechanics of chronic ankle instability (CAI) individuals has been widely investigated, but few have evaluated the internal foot mechanics in CAI. This study evaluated bone and soft tissue stress in CAI contrasted with copers and non-injured participants during a cutting task. Integrating scanned 3D foot shapes and free-form deformation, sixty-six personalized finite element foot models were developed.
View Article and Find Full Text PDFBiochim Biophys Acta Mol Cell Res
January 2025
Designing Future Health Initiative, Center for Promotion of Innovation Strategy, Head Office of Enterprise Partnerships, Tohoku University, Miyagi 980-8579, Japan.
Proteasome-dependent protein degradation and the digestion of peptides by aminopeptidases are essential for myogenesis. Methionine aminopeptidases (MetAPs) are uniquely involved in, both, the proteasomal degradation of proteins and in the regulation of translation (via involvement in post-translational modification). Suppressing MetAP1 and MetAP2 expression inhibits the myogenic differentiation of C2C12 myoblasts.
View Article and Find Full Text PDFJ Shoulder Elbow Surg
January 2025
Department of Clinical Anatomy, Graduate School of Medical and Dental Science, Tokyo Medical and Dental University, Tokyo, Japan.
Background: Biomechanical studies suggest that the triceps brachii muscle generates resistive force against valgus stress on the elbow during baseball pitching. However, given the parallel fiber orientation in the distal tendinous structure of the triceps brachii, the mechanism behind this anti-valgus force remains unclear. In the present study, we aimed to examine the anatomy of the distal tendinous structure of the triceps brachii using bony morphological, macroscopic, and histological methods.
View Article and Find Full Text PDFPLoS One
January 2025
School of Sport Science, Beijing Sport University, Beijing, China.
This study investigates the effect of varying tennis racket string tension on stroke effect and the dynamic response of the racket. Using the YSV dynamic acceleration signal acquisition system and a portable radar speed gun collect data on racket acceleration, stress-strain signals, and ball speed from 15 male athletes. Stroke accuracy and depth were assessed according to the International Tennis Number.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!