A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Cytosine-Rich Oligonucleotide and Electrochemically Reduced Graphene Oxide Nanocomposite for Ultrasensitive Electrochemical Ag Sensing. | LitMetric

Silver ions (Ag) are crucial in various fields, but pose environmental and health risks at high concentrations. This study presents a straightforward approach for the ultra-trace detection of Ag, utilizing a composite of a cytosine-rich oligonucleotide (CRO) and an electrochemically reduced graphene oxide (ERGO). Initially, ERGO was synthesized on a glassy carbon electrode (GCE) through the reduction of graphene oxide (GO) via cyclic voltammetry. A methylene blue-tagged CRO (MB-CRO) was then anchored to the ERGO surface through π-π interactions, resulting in the formation of an MB-CRO-modified ERGO electrode (MB-CRO/ERGO-GCE). The interaction with Ag ions induced the formation of silver-mediated C-Ag-C coordination, prompting the MB-CRO to adopt a hairpin structure. This conformational change led to the desorption of the MB-CRO from the ERGO-GCE, causing a variation in the redox current of the methylene blue associated with the MB-CRO. Electrochemical assays revealed that the sensor exhibits extraordinary sensitivity to Ag+ ions, with a linear detection range from 1 femtomolar (fM) to 100 nanomolars (nM) and a detection limit of 0.83 fM. Moreover, the sensor demonstrated high selectivity for Ag ions and several other benefits, including stability, reproducibility, and straightforward fabrication and operational procedures. Additionally, real sample analyses were performed using the modified electrode to detect Ag in tap and pond water samples, yielding satisfactory recovery rates.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11085715PMC
http://dx.doi.org/10.3390/nano14090775DOI Listing

Publication Analysis

Top Keywords

graphene oxide
12
cytosine-rich oligonucleotide
8
electrochemically reduced
8
reduced graphene
8
oligonucleotide electrochemically
4
oxide nanocomposite
4
nanocomposite ultrasensitive
4
ultrasensitive electrochemical
4
electrochemical sensing
4
sensing silver
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!