Background: There is a risk of cephalic vein injury during shoulder arthroscopy. However, limited data regarding its anatomic course are available.
Purpose: To analyze the positional relationship and factors affecting the distance between the coracoid tip and cephalic veins.
Study Design: Case series; Level of evidence, 4.
Methods: A total of 80 contrast-enhanced computed tomography images from 80 patients (mean age, 49.6 ± 20.3 years; 61 men) were retrospectively analyzed. The distance between the center of the coracoid tip and the vertical line through the cephalic vein was measured in the axial (D1) and sagittal (D2) planes. The distance between 1 cm lateral to the center of the coracoid tip and the vertical line through the cephalic vein was measured in the sagittal plane (D3). Each distance was compared according to patient sex and laterality. Associations between each distance and the patient's age, height, weight, and body mass index were investigated.
Results: The mean D1 was 18.4 ± 7.3 mm in 59 patients. The mean D2 was 23.4 ± 11.6 mm, and it was within 10 mm in 10 patients (12.5%). The mean D3 was 33.7 ± 12.2 mm. There was no significant difference in D1, D2, and D3 according to patient sex or laterality. A positive correlation was observed only between D3 and patient height ( = 0.320; = .034).
Conclusion: The cephalic vein was found to travel a mean of 23.4 mm distal and 33.7 mm distal to 1 cm lateral to the coracoid tip. Therefore, Care should be taken to avoid cephalic vein injury when creating an anterior inferior portal or 5-o'clock portal around these areas.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11080713 | PMC |
http://dx.doi.org/10.1177/23259671241248661 | DOI Listing |
Sci Rep
January 2025
Department of Cardiovascular, The Second Affiliated Hospital of Chongqing Medical University, No. 74, Linjiang Road, Yuzhong District, Chongqing, 400010, China.
In order to provide some references for vein approach selection in adrenal vein sampling (AVS), this retrospective study analyzed 325 cases of primary aldosteronism (PA) patients who underwent AVS via the upper extremity vein approach, comparing the differences in complications and visual analogue scale (VAS) scores through median cubital vein (MCV), basilic vein (BV), and cephalic vein (CV). The results indicated no significant difference in the incidence of venous spasm (right MCV vs. right BV vs.
View Article and Find Full Text PDFMed Intensiva (Engl Ed)
December 2024
Hospital Universitario Torrecárdenas, Almería, Spain.
Pacing Clin Electrophysiol
December 2024
Department of Cardiovascular Medicine, Fondazione Policlinico Universitario A. Gemelli IRCCS, Rome, Italy.
Introduction: Ultrasound (US)-guided axillary vein puncture is a safe and effective approach for cardiac implantable electronic device (CIED) implantation, and it is highly recommended by the current consensus document. However, only reports on small populations are available in the current literature regarding the comparison of this technique with other traditional approaches (subclavian vein blind puncture and cephalic vein surgical cutdown).
Purpose: We aimed to assess the effectiveness and safety of US- guided axillary vein puncture using a microintroducer kit for CIED implantation as compared to the aforementioned traditional approaches.
Ann Vasc Dis
December 2024
Hanoi Medical University, Hanoi, Vietnam.
We report our hospital-based experience in management strategies and outcomes for pediatric extremity vascular trauma at a major trauma center. A retrospective chart review was conducted on patients under 18 with extremity vascular injuries who had surgery between May 2021 and February 2023. Among 46 children, 16 (34.
View Article and Find Full Text PDFRes Vet Sci
December 2024
School of Veterinary Science, The University of Queensland, Gatton, QLD 4343, Australia. Electronic address:
Ketoprofen is a non-steroidal anti-inflammatory drug (NSAID) used to treat pain and inflammation in dogs. Despite having effective analgesic efficacy, prolonged oral administration has been associated with adverse effects. Transdermal delivery of ketoprofen has reduced the incidence of adverse effects in humans and could potentially be used in veterinary clinical medicine.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!