Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Statement Of Problem: Prefabricated and custom glass fiber posts have been successfully used to reconstruct endodontically treated teeth. However, the performance of computer-aided design and computer-aided manufacture (CAD-CAM) milled glass fiber posts is unclear.
Purpose: The purpose of this systematic review with meta-analysis was to compare the fracture and bond strength and cement layer thickness of CAD-CAM milled glass fiber posts with prefabricated or custom glass fiber posts.
Material And Methods: The protocol was registered in the Open Science Framework (http://osf.io/65jm7). Two reviewers searched the PubMed/MEDLINE, Web of Science, Embase, Scopus, and ProQuest databases for articles up to September 2023. In addition, the reference lists were hand searched. A meta-analysis was performed by using the RevMan 5.4 program. The risk of bias was assessed using the RoBDEMAT tool.
Results: After screening, a total of 18 studies were included. The CAD-CAM milled glass fiber posts showed higher fracture strength (P=.02; Standardized Mean Difference [SMD]: 0.57; 95% Confidence Interval [CI]: 0.07 to 1.07), bond strength (P=.010; SMD: 1.07; 95% CI: 0.26 to 1.89), and lower cement layer thickness (P=.009; SMD: -2.94; 95% CI: -5.15 to -0.73) when compared with prefabricated glass fiber posts. However, fracture strength (P=.53; SMD: 0.38; 95% CI: -0.79 to 1.54) and bond strength (P=.90; SMD: -0.05; 95% CI: -0.81 to 0.72) were statistically similar between CAD-CAM milled and custom glass fiber posts. Significant and substantial heterogeneity was observed in all meta-analyzes (P<.01; I>60%). The studies sufficiently reported most domains related to bias, except for randomization of samples, sample size rationale and reporting and operator blinding.
Conclusions: CAD-CAM milled and custom glass fiber posts provide an effective and safe option for restoring endodontically treated teeth, especially for weakened teeth or enlarged root canals. However, further well-designed clinical research is recommended to strengthen these findings.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.prosdent.2024.03.041 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!