A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

An Operating Stiffness Controller for the Medical Continuum Robot Based on Impedance Control. | LitMetric

An Operating Stiffness Controller for the Medical Continuum Robot Based on Impedance Control.

Cyborg Bionic Syst

Key Laboratory of Mechanism Theory and Equipment Design of Ministry of Education, School of Mechanical Engineering, Tianjin University, Tianjin 300072, China.

Published: May 2024

Continuum manipulators can conform to curvilinear paths and manipulate objects in complex environments, which makes it emerging to be applied in minimally invasive surgery (MIS). However, different and controllable operating stiffness of the continuum manipulator is required during different stages of surgery to achieve safe access or stable and precise operation. This work proposes an operating stiffness controller (OSC) for the typical tendon-driven continuum manipulator based on the variable impedance control method with Lagrangian dynamic modeling. This controller can adjust the operating stiffness by modifying the driving forces along the driving tendons of the continuum manipulator without changing its material or structure. The proposed OSC converts the damping and stiffness matrices of the impedance control into variable parameters. This merit allows it to dynamically adjust the operating stiffness of the continuum manipulator according to the desired constant or time-varying stiffness. Furthermore, the OSC stability can be proven based on a Lyapunov function, and its stiffness control performances have been analyzed and evaluated in both simulations and experiments. The OSC controller generated average relevant error values of 7.82% and 3.09% for the operating stiffness control experiments with constant and time-varying desired stiffness, respectively. These experimental results indicate that the OSC has high accuracy, stability, and strong robustness in the operating stiffness control tasks.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11077269PMC
http://dx.doi.org/10.34133/cbsystems.0110DOI Listing

Publication Analysis

Top Keywords

operating stiffness
28
continuum manipulator
16
impedance control
12
stiffness control
12
stiffness
10
stiffness controller
8
stiffness continuum
8
adjust operating
8
constant time-varying
8
operating
7

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!