The USP Rotating Basket Dissolution Testing Apparatus 1 is listed in the USP as one of the tools to assess dissolution of oral solid dosage forms. Baskets of different mesh sizes can be used to differentiate between dissolution profiles of different formulations. Here, we used Particle Image Velocimetry (PIV) to study the hydrodynamics of the USP Apparatus 1 using baskets with different mesh openings (10-, 20- and 40-mesh) revolving at 100 rpm, when the vessel was filled with 500 mL. The velocity profiles throughout the liquid were found to vary significantly using baskets of different mesh sizes, typically increasing with increased size of the opening of the basket mesh, especially for axial and radial velocities. This, in turn, resulted in a significantly different flow rate through the basket, which can be expected to significantly impact the dissolution rate of the drug product. A comparison between the results of this work with those of a previous study with a 900-mL fill volume (Sirasitthichoke et al., Intern. J. Pharmaceutics, 2021, 607: 120976), shows that although the hydrodynamics in the USP Apparatus 1 changed with fill level in the vessel, the flow rate through the basket was not significantly affected. This implies that tablets dissolving in the two systems would experience similar tablet-liquid medium mass transfer coefficients, and therefore similar initial dissolution rates, but different dissolution profiles because of the difference in volume.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.ijpharm.2024.124209 | DOI Listing |
Elife
October 2024
Risk-Management Ecology Lab, Department of Ecology, Evolution & Behavior The Alexander Silberman Institute of Life Sciences, The Hebrew University of Jerusalem, Jerusalem, Israel.
Litter decomposition is expected to be positively associated with precipitation despite evidence that decomposers of varying sizes have different moisture dependencies. We hypothesized that higher tolerance of macro-decomposers to aridity may counterbalance the effect of smaller decomposers, leading to similar decomposition rates across climatic gradients. We tested this hypothesis by placing plant litter baskets of different mesh sizes in seven sites along a sharp precipitation gradient, and by characterizing the macro-decomposer assemblages using pitfall trapping.
View Article and Find Full Text PDFHeliyon
September 2024
Science Laboratory Technology Department, Yaba College of Technology, Yaba, Lagos State, Nigeria.
The possibility of different agrowastes to self-ignite under ambient condition, due to exothermic reactions between their surface molecules and air or other oxidizing agents which are conveyed into the void volume between the particles, exists. It is imperative to investigate the self-ignition ability of these harzadous waste products causing environmental pollution after the milling process to avoid sudden fire outbreaks. In this study, the self-ignition attributes of corn cob, wheat bran and rice husk residues in ambient air from biomass gasification was investigated by evaluating their self-ignition temperatures using DIN EN 15188:2021 standard and Frank-Kamenetzkii's theory of thermal explosion at varying basket volume.
View Article and Find Full Text PDFInt J Pharm
June 2024
Otto H. York Department of Chemical and Materials Engineering, New Jersey Institute of Technology, Newark, NJ 07102-1982, USA. Electronic address:
The USP Rotating Basket Dissolution Testing Apparatus 1 is listed in the USP as one of the tools to assess dissolution of oral solid dosage forms. Baskets of different mesh sizes can be used to differentiate between dissolution profiles of different formulations. Here, we used Particle Image Velocimetry (PIV) to study the hydrodynamics of the USP Apparatus 1 using baskets with different mesh openings (10-, 20- and 40-mesh) revolving at 100 rpm, when the vessel was filled with 500 mL.
View Article and Find Full Text PDFZhonghua Jie He He Hu Xi Za Zhi
May 2023
Department of Respiratory and Critical Care Medicine, the First Affiliated Hospital of Guangzhou Medical University, National Center for Respiratory Medicine, National Clinical Research Center for Respiratory Disease, State Key Laboratory of Respiratory Disease, Guangzhou Institute of Respiratory Health, Guangzhou 510120, China.
Airway foreign body is the unintentional entry of objects into the larynx, trachea, or bronchi, causing airway obstruction, severe coughing, wheezing, breathing difficulties, or even asphyxiation. It is a common emergency condition in respiratory, critical care, emergency, otolaryngology, and pediatric departments, . With the popularization of flexible bronchoscopic techniques, endoscopic foreign body removal has been widely used in adults and children.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!