The increasing signal-to-noise ratio (SNR) is the main reason to use ultrahigh field MRI. Here, we investigate the dependence of the SNR on the magnetic field strength, especially for small animal applications, where small surface coils are used and coil noise cannot be ignored. Measurements were performed at five field strengths from 3 to 14.1 T, using 2.2-cm surface coils with an identical coil design for transmit and receive on two water samples with and without salt. SNR was measured in a series of spoiled gradient echo images with varying flip angle and corrected for saturation based on a series of flip angle and T measurements. Furthermore, the noise figure of the receive chain was determined and eliminated to remove instrument dependence. Finally, the coil sensitivity was determined based on the principle of reciprocity to obtain a measure for ultimate SNR. Before coil sensitivity correction, the SNR increase in nonconductive samples is highly supralinear with B , depending on distance to the coil, while in the conductive sample, the growth is smaller, being around linear close to the surface coil and increasing up to a B dependence when moving away from the coil. After sensitivity correction, the SNR increase is independent of loading with B . This study confirms the supralinear increase of SNR with increasing field strengths. Compared with most human measurements with larger coil sizes, smaller surface coils, as mainly used in animal studies, have a higher contribution of coil noise and thus a different behavior of SNR at high fields.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1002/nbm.5168 | DOI Listing |
ACS Appl Mater Interfaces
January 2025
Textile and Clothing College, Qingdao University, Qingdao 266071, China.
Fiber-based strain sensors, as wearable integrated devices, have shown substantial promise in health monitoring. However, current sensors suffer from limited tunability in sensing performance, constraining their adaptability to diverse human motions. Drawing inspiration from the structure of the spiranthes sinensis, this study introduces a unique textile wrapping technique to coil flexible silver (Ag) yarn around the surface of multifilament elastic polyurethane (PU), thereby constructing a helical structure fiber-based strain sensor.
View Article and Find Full Text PDFLab Chip
January 2025
Institute of Translational Medicine, Department of Health Sciences and Technology, ETH Zürich, 8092 Zürich, Switzerland.
Proteases, an important class of enzymes that cleave proteins and peptides, carry a wealth of potentially useful information. Devices to enable routine and cost effective measurement of their activity could find frequent use in clinical settings for medical diagnostics, as well as some industrial contexts such as detecting on-line biological contamination. In particular, devices that make use of readouts involving magnetic particles may offer distinct advantages for continuous sensing because material they release can be magnetically captured downstream and their readout is insensitive to optical properties of the sample.
View Article and Find Full Text PDFMycoKeys
December 2024
Yunnan Provincial Key Laboratory for Conservation and Utilization of In-forest Resource, the Key Laboratory of Forest Resources Conservation and Utilization in the Southwest Mountains of China Ministry of Education, Southwest Forestry University, Kunming 650224, China Southwest Forestry University Kunming China.
Three new fungal species, , and , are proposed based on a combination of the morphological features and molecular evidence. The taxon is characterized by the coriaceous basidiomata with a cream surface, cylindrical basidia, straight, 4-celled, subglobose or ovoid probasidia and thin-walled, narrowly cylindrical basidiospores with septa, measuring as 7-9 × 3.5-4.
View Article and Find Full Text PDFMaterials (Basel)
December 2024
GRIMAT Engineering Institute Co., Ltd., Beijing 101407, China.
Titanium alloy coiled tubing (CT) has great superiority while operating in deep wells with severe conditions, but it faces serious challenges during roll forming like high springback, edge cracking and surface wearing. In order to utilize the high precision and high efficiency production of titanium alloy CT, it is urgently necessary to develop a detailed process design. Based on the W-forming strategy and the cubic curve of the strip edge projection, the flower pattern and roll design for the 21-pass roll forming process were completed.
View Article and Find Full Text PDFFoods
December 2024
College of Food Science, Southwest University, Chongqing 400715, China.
The aim of this study was to investigate the promotion of linoleic acid (OLA)-induced myofibrillar protein (MP) oxidation by boiling treatment. The effect of the boiling treatment on grass carp MP oxidation induced by OLA was investigated. The total sulfhydryl content, fluorescence intensity, and amino acid content were reduced with the increasing OLA concentration after the boiling treatment, while the boiled oxidized MP's carbonyl content (4.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!