A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Unraveling the nature of sensing in electrostatic MEMS gas sensors. | LitMetric

Unraveling the nature of sensing in electrostatic MEMS gas sensors.

Microsyst Nanoeng

Systems Design Engineering, University of Waterloo, 200 University Ave W, Waterloo, N2L 3G1 ON Canada.

Published: May 2024

This paper investigates the fundamental sensing mechanism of electrostatic MEMS gas sensors. It compares among the responsivities of a set of MEMS isopropanol sensors before and after functionalization, and in the presence and absence of electrostatic fields when operated in static and dynamic detection modes. In the static mode, we found that the sensors do not exhibit a measurable change in displacement due to added mass. On the other hand, bare sensors showed a clear change in displacement in response to isopropanol vapor. In the dynamic mode, functionalized sensors showed a measurable frequency shift due to the added mass of isopropanol vapor. In the presence of strong electrostatic fields, the measured frequency shift was found to be threefold larger than that in their absence in response to the same concentration of isopropanol vapor. The enhanced responsivity of dynamic detection allows the sensors to measure the vapor mass captured by the functional material, which is not the case for static detection. The detection of isopropanol by bare sensors in static mode shows that change in the medium permittivity is the primary sensing mechanism. The enhanced responsivity of dynamic mode sensors when operated in strong electrostatic fields shows that their sensing mechanism is a combination of a weaker added mass effect and a stronger permittivity effect. These findings show that electrostatic MEMS gas sensors are independent of the direction of the gravitational field and are, thus, robust to changes in alignment. It is erroneous to refer to them as 'gravimetric' sensors.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11074296PMC
http://dx.doi.org/10.1038/s41378-024-00688-3DOI Listing

Publication Analysis

Top Keywords

electrostatic mems
12
mems gas
12
gas sensors
12
sensing mechanism
12
electrostatic fields
12
isopropanol vapor
12
sensors
11
dynamic detection
8
static mode
8
mode sensors
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!