AI Article Synopsis

  • PFASs are a widespread contaminant linked to health issues, particularly affecting infants due to their ability to disrupt endocrine functions.
  • A new screening method called MSI-NACE-MS/MS was developed to efficiently analyze low levels of PFASs, like PFOA and PFOS, in serum using a straightforward extraction process.
  • This method provides rapid, precise quantification of PFASs in maternal serum samples, highlighting both its utility for monitoring environmental exposure and its implications for maternal health and potential chronic diseases in children.

Article Abstract

Perfluoroalkyl substances (PFASs) are a major contaminant class due to their ubiquitous prevalence, persistence, and putative endocrine disrupting activity that may contribute to chronic disease risk notably with exposures early in life. Herein, multisegment injection-nonaqueous capillary electrophoresis-tandem mass spectrometry (MSI-NACE-MS/MS) is introduced as a high throughput approach for PFAS screening in serum samples following a simple methyl--butyl ether (MTBE) liquid extraction. Separation and ionization conditions were optimized to quantify low nanomolar concentration levels of perfluorooctanoic acid (PFOA) and perfluorooctanesulfonic acid (PFOS) from serum extracts when using multiple reaction monitoring under negative ion mode conditions. Multiplexed separations of PFOA and PFOS were achieved with excellent throughput (<3 min/sample), adequate concentration sensitivity (LOD ∼ 20 nM, S/N = 3) and good technical precision over three consecutive days of analysis (mean CV = 9.1%, n = 84). Accurate quantification of PFASs was demonstrated in maternal serum samples (n = 16) when using MSI-CE-MS/MS following pre-column sample enrichment with median concentrations of 3.46 nM (0.7-9.0 nM) and 3.29 nM (1.5-6.6 nM) for PFOA and PFOS, respectively. This was lower than average PFAS exposures measured in pregnant women who had serum collected prior to 2009 likely due to subsequent phase out of their production. Overall, this method offers a convenient approach for large-scale biomonitoring of environmental exposures to legacy PFASs and their emerging replacements that is relevant to maternal health and chronic disease risk assessment in children.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10989087PMC
http://dx.doi.org/10.1002/ansa.202000053DOI Listing

Publication Analysis

Top Keywords

multisegment injection-nonaqueous
8
injection-nonaqueous capillary
8
capillary electrophoresis-tandem
8
electrophoresis-tandem mass
8
mass spectrometry
8
rapid biomonitoring
4
biomonitoring perfluoroalkyl
4
perfluoroalkyl substance
4
substance exposures
4
exposures serum
4

Similar Publications

Orthogonal separation techniques coupled to high-resolution mass spectrometry are required for characterizing the human lipidome, given its inherent chemical and structural complexity. However, electrophoretic separations remain largely unrecognized in contemporary lipidomics research compared to established chromatographic and ion mobility methods. Herein, we introduce a novel derivatization protocol based on 3-methyl-1--tolyltriazene (MTT) as a safer alternative to diazomethane for quantitative phospholipid (PL) methylation (∼90%), which enables their rapid analysis by multisegment injection-nonaqueous capillary electrophoresis-mass spectrometry (MSI-NACE-MS).

View Article and Find Full Text PDF

Optimal dietary intake of omega-3 long-chain polyunsaturated fatty acids (n3-LCPUFAs) is critical to human health across the lifespan. However, omega-3 index (O3I) determination is not routinely assessed due to complicated procedures for n3-LCPUFA analysis from the phospholipid (PL) fraction of erythrocytes. Herein, a high-throughput method for lipidomics based on multisegment injection-nonaqueous capillary electrophoresis-mass spectrometry was applied to identify circulating PLs as surrogate biomarkers of O3I in two randomized placebo-controlled trials.

View Article and Find Full Text PDF

Background: Sparse data exists on the utility of individual serum non-esterified fatty acids (NEFAs) as clinical and dietary biomarkers and how reporting methods could affect these associations. We investigated the associations of 19 serum NEFAs expressed as µM or mol%, with self-reported dietary intake data, and cardiometabolic health indicators in pregnant women.

Methods: In this cross-sectional study, 273 pregnant women in their second trimester each completed a semi-quantitative food-frequency questionnaire and provided fasting serum samples.

View Article and Find Full Text PDF

New methods are needed for global lipid profiling due to the complex chemical structures and diverse physicochemical properties of lipids. Herein we introduce a robust data workflow to unambiguously select lipid features from serum ether extracts by multisegment injection-nonaqueous capillary electrophoresis-mass spectrometry (MSI-NACE-MS). An iterative three-stage screening strategy is developed for nontargeted lipid analyses when using multiplexed electrophoretic separations coupled to an Orbitrap mass analyzer under negative ion mode.

View Article and Find Full Text PDF
Article Synopsis
  • PFASs are a widespread contaminant linked to health issues, particularly affecting infants due to their ability to disrupt endocrine functions.
  • A new screening method called MSI-NACE-MS/MS was developed to efficiently analyze low levels of PFASs, like PFOA and PFOS, in serum using a straightforward extraction process.
  • This method provides rapid, precise quantification of PFASs in maternal serum samples, highlighting both its utility for monitoring environmental exposure and its implications for maternal health and potential chronic diseases in children.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!