Synopsis: High volume cataract lists are cost-effective, reduce waiting times, and facilitate surgical teaching. We propose a stepwise training model that incorporates human factor principles and a reflective pedagogical approach, which has not been documented previously.
Background/aims: Surgical training in ophthalmology is effective when a modular approach is utilised. High volume lists further enhance training by increasing exposure to a newer way of learning and working. We evaluated the efficiency and safety of trainee-assisted cataract surgery across a single NHS eye unit and an independent sector (IS) provider.
Methods: We examined results from audits of surgical efficiency and safety in trainee-assisted high-volume lists, including a single-centre comparative evaluation of consultant-only and trainee lists. The quantitative and qualitative information gained from these projects helped us to implement a modular, structured training programme that utilises a reflective cycle of pedagogy, suitable for any grade of trainee.
Results: Our projects included an audit following cataract surgery performed by a surgical trainee over a 5-month period, which showed excellent post-op refractive results and no cases of intra-operative and post-operative complications. A single-centre observational study demonstrated comparable surgical throughput and safety results for trainee and solo consultant high volume lists. Systemic and ocular complication rates were reported to be similar for low and medium risk cataract surgery among trainee supervised IS and NHS lists.
Conclusion: Cataract surgery outcomes and patient feedback support the effectiveness of the surgical training model. Combining Gibbs' reflective cycle of critical reflection with the International Council of Ophthalmology's principles helped us to develop the QM Model of modular teaching for cataract surgery, which we believe is suitable for utilisation in all surgical centres in the NHS and IS settings, for both low volume and high-volume surgical lists regardless of trainee experience.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11073136 | PMC |
http://dx.doi.org/10.2147/OPTH.S451594 | DOI Listing |
Ophthalmol Ther
January 2025
Rocky Vista University, Englewood, CO, USA.
Introduction: This retrospective, consecutive, real-world case series assessed the efficacy and safety of third-generation trabecular micro-bypass stent implantation (iStent infinite) with phacoemulsification in patients with mild-to-moderate primary open-angle glaucoma (POAG).
Methods: Patients underwent phacoemulsification combined with implantation of iStent infinite (containing three stents) by a single U.S.
Ophthalmol Ther
January 2025
Pediatric Ophthalmology and Strabismus Division, King Khaled Eye Specialist Hospital, Al Urubah Branche Rd., West Building 2nd Floor, 11462, Riyadh, Saudi Arabia.
Introduction: Persistent fetal vasculature (PFV) is a congenital anomaly associated with significant surgical challenges, including a high risk of postoperative retinal detachment (RD). This study aimed to evaluate the impact of surgical approach and axial length (AL) on RD risk and visual outcomes in pediatric PFV management.
Methods: A retrospective cohort study was conducted involving 76 eyes of 74 patients who underwent cataract surgery for PFV between 2014 and 2022.
Med J Malaysia
January 2025
Universiti Sains Malaysia, School of Medical Sciences, Department of Ophthalmology and Visual Science, Health Campus, Kubang Kerian, Kelantan, Malaysia.
Introduction: Cataract is a leading cause of visual impairment globally and in Malaysia, with surgery being the definitive treatment. While intracapsular cataract extraction (ICCE) is now less commonly performed due to advancements in surgical techniques, it remains essential in specific cases, such as those with weak zonular support. This study aims to evaluate the incidence, clinical profiles, and visual outcomes of patients who underwent ICCE, with or without intraocular lens (IOL) implantation, at Hospital Melaka, Malaysia, over the past decade.
View Article and Find Full Text PDFCurr Eye Res
January 2025
Sussex Eye Hospital, Brighton & Sussex University Hospitals NHS Trust, Brighton, UK.
Purpose: To assess the relationship between angle kappa (apparent chord mu) and ocular parameters in cataract patients.
Methods: In this cross-sectional study, the data on apparent chord mu, age, axial length, anterior chamber depth, anterior and posterior mean keratometry, mean total keratometry, white-to-white, central corneal thickness and lens thickness were collected for consecutive cataract patients. Correlation (Pearson) between chord mu and the other ocular parameters was calculated.
GMS Ophthalmol Cases
December 2024
Universidade Federal do Paraná (UFPR), Curitiba, Brazil.
Purpose: Idiopathic elevated episcleral venous pressure (IEEVP) or Radius-Maumenee syndrome (RMS) is a rare disease without any identified underlying cause. An increasing episcleral venous pressure (EVP) leads to raised intraocular pressure (IOP) and consequently glaucomatous damage of the optic nerve. The objective of this paper is to report this rare condition as well as its clinical management.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!